Reference : SGP_AVS_SW_ATLAS-05-05
Classification :
COMPANY
RESTRICTED
Version :
0.17
Project
:
ATLAS_DSW
Status :
Proposed
Chapter
:
User
Manual
Date :
2006-09-12
Section
:
Diagnostic Software (Leco+)
© Philips Electronics N.V. 2006
Philips Semiconductors
Page 109 of 124
Nucleus Name
DS_DTTM_ AvVideoStandardSet
Nucleus Number
2228
Description
Configures the Mojo video channel to the given video standard.
Technical
- Send the DTTM command ID 1501, together with supplied input value.
Execution Time
< 1 sec.
User Input
VideoStandard: Video standard to set the channel to (0=PAL, 1=SECAM)
Error Number
Description
222800
Succeeded in configuring the Mojo video channel
222801
Insufficient number of input data supplied
222802
Non-existent video standard
222803
Configuring the Mojo video channel was not successful
222804
Communication with the DTT Module failed.
222805
DTT Module initialisation failed.
Example
DS:> 2228 0
222800:
Test OK @
1
Nucleus Name
DS_DTTM_ AvVideoOutputSet
Nucleus Number
2229
Description
Configures the video output to the selected video standard.
Technical
- Send the DTTM command ID 1504, together with supplied input values.
Execution Time
< 1 sec.
User Input
1. VideoDAC : The video DAC to configure
0 = RGB / YUV / YC (TV DAC's)
1 = CVBS / Y (TV DAC)
2 = YC / CVBS (VCR DAC's)
2. VideoOutput: The video output to set the DAC's to
0 = RGB or CVBS or YC (resp. the chosen DAC's)
1 = YUV or YC or CVBS
2 = YC
Error Number
Description
222900
Video output could be set successfully
222901
Insufficient number of input data supplied
222902
One of the parameter values is out of range
222903
Video output could not be set
222904
Communication with the DTT Module failed
222905
DTT Module initialisation failed.
Example
DS:> 2229 0 1
222900:
Test OK @
2
Nucleus Name
DS_DTTM_FreRegisterRead
Nucleus Number
2230
Description
Reads a single byte of data out of a demodulator register.
Technical
- Send the DTTM command ID 3601, together with supplied input value.
Execution Time
< 1 sec.
User Input
Address: register address to read from
Error Number
Description
223000
The selected address register could be read successfully
223001
Insufficient number of input data supplied
223002
The register address value is out-of-range
223003
The selected address register could not be read
223004
Communication with the DTT Module failed
223005
DTT Module initialisation failed.
Example
DS:> 2230 0x12
223000: The value of this register: 0x00
Test OK @
3
Summary of Contents for DVDR3575H/
Page 152: ...Front Board Waveforms Emitter 7106 7108 2140 I102 1110 I103 1110 ...
Page 153: ...Layout Front Board Bottom View Front Board Bot View 3139 243 36464_sh132_a4 eps 2007 07 11 ...
Page 155: ...Layout Front Board Top View Front Board Top View 3139 243 36464_sh132_a4 eps 2007 07 11 ...
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......
Page 164: ...Layout Analog Bottom View Analog Bottom 3139 243 37473_sh132_a3 eps 2007 07 11 ...
Page 166: ...Layout Analog Top View Analog Top 3139 243 37473_sh132_a3 eps 2007 07 11 ...
Page 172: ... 1 LUFXLW LDJUDPV DQG 3 D RXWV D RXW LJLWDO 7RS 9LHZ ...
Page 182: ... 1 D RXW LJLWDO RWWRP 9LHZ LUFXLW LDJUDPV DQG 3 D RXWV ...
Page 187: ...Layout HDMI Bottom View HDMI Bot View 3139 243 36753_sh132_a4 eps 2007 07 11 ...
Page 189: ...Layout HDMI Bottom View HDMI Top View 3139 243 36753_sh132_a4 eps 2007 07 11 ...