PFT LOTUS XL light 400 V Overview – Operation – Spare Parts Lists
Preparation of the machine
24
2017-01-16
18.4 Water supply connection
Fig. 27: Water connection without
a booster pump
Water connection to water supply network without booster pump:
1. Check whether the dirt trap sieve in the water inlet (1) is clean.
2. Dirt trap sieve for Geka coupling:
Dirt trap sieve for Geka coupling:
Item number 20152000
Fig. 28: Water connection with
a booster pump
Water connection to water supply network with booster pump
3. Check whether the sieve insert in the dirt trap (2) is clean.
4. If necessary, remove the sieve insert from the dirt trap
and clean it.
Sieve insert ES 30-1" A:
Item number 20152011
5. Clean and bleed the water hose for the water mains supply.
4
3
Fig. 29: Water connection
6. Connect the water hose to the water inlet (3) or booster pump.
7. Check whether the water hose (4) is connected to the middle
body water inlet.
NOTE!
Only use clean water that is free of particulates.
The minimum pressure is 2.5 bar when the
machine is running.
1
2