PFT LOTUS XL light 400 V Overview – Operation – Spare Parts Lists
Maintenance tasks
2017-01-16
37
30 Maintenance tasks
30.1 Dirt trap sieve
Fig. 47: Dirt trap sieve in the water inlet
Check the dirt trap sieve in the water inlet on a daily basis:
1. Remove the dirt trap sieve from the Geka coupling.
2. Clean the dirt trap sieve.
3. Replace the sieve if dirt is severe.
4. Replace the dirt trap sieve
.
Dirt trap sieve for Geka coupling:
Item number 20152000
Performed by operator.
30.2 Sieve insert
Fig. 48: Checking the sieve insert
Checking the sieve insert in the dirt trap weekly:
1. Unscrew the dirt trap and take out the sieve insert.
2. Clean the sieve insert.
3. Replace the sieve insert if dirt is severe.
4. Replace the dirt trap sieve
.
Sieve insert for dirt trap:
Item number 20152011
Performed by operator.
30.3 After performing maintenance
After maintenance has been completed, carry out the following steps
before switching on.
1.
Check that all previously loosened screw connections have
a tight fit.
2.
Check that all previously removed protective devices and covers
have been properly reattached.
3.
Ensure that all tools, materials and other equipment have been
removed from the work area.
4.
Clean the work area and remove any traces of escaped material
(e.g. liquids, processing material etc.).
5.
Ensure that all safety devices are functioning properly.
1
1