PFT LOTUS XL light 400 V Overview – Operation – Spare Parts Lists
Troubleshooting
2017-01-16
33
26.4 Table of malfunctions
Malfunction
Possible cause
Solution
Performed by
Machine
does not start
Water
Water pressure too low
Check the water supply,
clean the dirt trap sieves
Operator
The water pressure is too low
Install booster pump
Operator
Machine
does not start
Power
Power cable is defective
Repair the power cable
Service
technician
Main switch not activated
Turn on the main switch
Operator
FI circuit breaker triggered
Reset the FI circuit breaker
Service
technician
Machine
does not start
Material
Too much thickened material
in the mixing tube
Drain the mixing tube and restart
machine
Operator
Material in mixing tube too dry
Drain the mixing tube and restart
machine
Operator
Water is not
flowing
Solenoid valve
(bore hole in membrane blocked)
Clean the solenoid valve
Service
technician
Solenoid coil defective
Replace the solenoid coil
Service
technician
Water inlet on middle body
blocked
Clean the water inlet
on middle body
Operator
Needle valve closed
Open the needle valve
Operator
Cable to solenoid valve defective
Replace the cable to solenoid valve
Service
technician
Mixer motor
will not start
Mixer motor defective
Replace the mixer motor
Service
technician
Defective connection cable
Replace the connection cable
Service
technician
Machine
stops after
a short period
Water inlet screen dirty
Clean or replace the screen
Operator
Hose connection or water
line too small
Enlarge the hose connection
or water line
Operator
Water intake line too long or intake
pressure too weak
Connect an additional booster
pump, if necessary
Service
technician