Input
57
Description of the functions
Input mode
This function is used to change from the initial state to the input mode.
Further settings
This function is used to call up the menu for entering further settings.
Sealing mode
This function is used to change to the sealing mode.
Setting the sensitivity to change in material ply
This function is used to enter the sensitivity to a change in the ply thickness. The thicker the
material (the ply change), the higher the level for this value.
These functions are used to set the time for reaction to a change in ply. This is the time
which passes from the initial recognition of a ply change to the actual reaction of the machi-
ne. The more even the structure of the work material, the lower the setting for this value.
Each time there is a change in the material ply, a signal sounds.
The setting of both values for the sensitivity is correct, if an actual ply change is
recognized reliably and quickly, and if during the sealing of the normal plies the-
re is no case of a “recognition” (no signal).
11
.03.01
Automatic ply recognition
In this menu all relevant parameters are determined, which are required for the automatic
ply recognition.
Switch on the machine.
Call up the input mode.
Call up further settings.
Call up the menu for entering the parameters for the automatic ply recognition.
●
●
●
●
8
4