88
Adjustment
Fig. 13 - 21
●
Switch on the machine and set parameter "
610
" at "
4
" (button gauge: centre).
●
Push down work clamp
1
by hand.
●
Adjust work clamp
1
(screws
2
) in accordance with
requirement 1
.
●
Check the other needle entry positions for values "
6
" and "
7
" of parameter "
610
" in accor-
dance with
requirement 2
.
●
Connect the machine to the pneumatic power supply and check the setting again.
●
If necessary correct the position of work clamp
1
(screws
2
).
●
Switch off the machine and disconnect it from the pneumatic power supply.
2
2
104-017
1
4
3
Requirement
1. After selecting value "
4"
for parameter "
610",
work clamp
1
should be centred to the
needle and be positioned at the front edge of the needle hole.
2. When value "
6"
is set, needle
3
should be positioned to the left of work clamp
1,
and
when value "
7"
is set, needle
3
should be positioned to the right of it.
13
.23
Aligning the work clamp
(only on subclass -4/..)