72
Adjustment
To change the sensor board, it is imperative to observe the following work-
steps!
Electric voltage!
Danger of an electric shock if handled incorrectly!
●
Completely remove the needle drive unit (plugs remain connected).
●
Loosen screws
2
.
●
Lock eccentric
1
by placing the locking pin
3
(part no.
13
-
030
272
-
05
) in the locking hole
of the mounting bracket.
Fig. 13 - 06
1
2
2
3
5
4
6
1
Requirement
1. When parameter "
610"
is set at "
4",
the recess in eccentric
1
should match the locking
hole in the mounting bracket.
2. The switch lug of eccentric
1
should be axially centred to the hybrid light barrier of the
sensor board.
13
.09
Sensor board of the needle drive
(in dismantled condition)