Adjustment
110
Group
Parameter
Description
Setting
range
Set
value
200
208
1 – 120 =
Display thread size of last program
(max. 120 stitches)
0 =
Display calculated optimum threshold
(for input in para. "206"
0 -120
209
Air jet
I = off, II = on
Attention!
If the thread wiper is attached, the air jet
must be switched off!
I, II
I
210
Turn-on time air jet [s]
0 - 10
1
211
Initialize clamp at sewing start
I = off, II = on
I, II
I
400
401
Raise clamp delay [s]
0,00 - 1,50
0
402
Start delay after clamp lowered [s]
0,00 - 1,50
0
403
Delay before thread trimming [s] (Switch
time till thread wiper forwards)
0,00 - 2,00
0,06
404
Thread cutting time [s]
0,00 - 2,00
0,06
405
Time between "thread clamp closed" and
"thread puller on" [s]
0,00 - 2,00
0,10
406
Waiting time for thread puller [s]
0,00 - 2,00
0,30
408
Time for added feature clamp / non-pres-
surized insert plate [s]
0,00 - 1,50
1
500
501
Soft start stitches
Soft start speed (spm)
0 - 15
0 - 2000
0
500
503
Extra stitches at start (start stitches)
0 - 4
0
504
Delay time thread clamp open at
beginning of seam [s]
0 - 2
0,02
506
Angle position for "end knotting on"
0 - 127
40
507
Angel position for "end knotting off"
0 - 127
70
Summary of Contents for 3307-1 Series
Page 124: ...124 Circuit diagram View Version 13 11 06 91 191 511 95 Part 1...
Page 125: ...125 91 191 511 95 Part 2 Version 13 11 06 Circuit diagram View...
Page 126: ...126 Circuit diagram View Version 13 11 06 91 191 511 95 Part 3...
Page 127: ...127 91 191 511 95 Part 4 Version 13 11 06 Circuit diagram View...
Page 128: ...128 Circuit diagram View Version 13 11 06 91 191 511 95 Part 5...
Page 129: ...Note...