Mounting and commissioning the machine
25
8
.01.03
Connecting the plug-in connections and earth cable
●
Connect all plugs as labelled in the control box.
●
Screw the earth cable from the machine and from the main switch to earth point A.
●
Connect earth points A and B with an earth cable.
●
Screw the earth cable of plug
1
to earth point B.
Fig. 8 - 03
106-051
A
1
B
Summary of Contents for 3307-1 Series