Adjustment
85
Fig. 13 - 18
●
Switch on the machine and bring the needle into the relevant position (value "
1
,
2
or
3
")
with parameter "
610
".
●
Adjust thread loop support
1
(screws
2
) in accordance with the
requirement.
●
Switch off the machine.
The thread loop support
1
is also used as a knife guard.
104-014
0,5 mm
2
1
Requirement
Both at the extreme right point of penetration and at the extreme left point of penetration
the needle should be at a distance of
approx. 0.5 mm
from the thread loop support
1.