Accutrac 360-t Tunnel
3.2.
Appendix B: I/O & Circuit Breaker Lists
Cable
Color
Input Card
Wire Color
Input/
Wire #
Description
white
1000
E-Stop ok, 360 Control Panel Door
brown
1001
Remote E-Stop ok
Optional, If not used jumper to 24VDC(+)
green
1002
Machine Reset, 360 Control Panel Door
yellow
1003
Home Prox Made
grey
1004
Exit Prox Made
pink
1005
Entrance Prox Made
blue
1006
SPARE
red
1007
Bridge PE-1 clear (A Freq)
black
1008
Bridge PE-2 clear (B Freq)
violet
1009
DS Trolley Retracted
grey/pink
1010
DS Trolley Extended
red/blue
1011
DS Impact Sensor Top not ok (Left/Right)
white/green
1012
DS Impact Sensor Bottom not ok (Front/Rear)
brown/green
1013
PS Trolley Retracted
white/yellow 1014
PS Trolley Extended
yellow/brown 1015
PS Impact Sensor Top not ok (Left/Right)
white
1016
PS Impact Sensor Bottom not ok (Front/Rear)
brown
1017
SPARE
green
1018
Profile XP-1 clear (B Freq) (Bottom)
yellow
1019
Profile XP-2 clear (A Freq)
grey
1020
Profile XP-3 clear (B Freq)
pink
1021
Profile XP-4 clear (A Freq) (Top)
If no Top Washer, Jumper to 24VDC(+)
blue
1022
Pulse Switch (From Tunnel Controller Input/ Pulse Switch)
Isolation Relay (*)
red
1023
Entrance Photo-Eye (From Tunnel Controller Input/ Photo Eye)
Isolation Relay (*)
black
1024
Conveyor Running (From Tunnel Controller Output/ Conv motor starter)Isolation Relay (*)
violet
1025
Start 360 Extend & Enable (From Tunnel Controller Output)
Isolation Relay (*)
grey/pink
1026
Start Top HP Pump & Top Oscillator (From Tunnel Controller Output)
Isolation Relay (*)
red/blue
1027
Start Side HP Pump & Side Oscillators (From Tunnel Controller Output)Isolation Relay (*)
white/green
1028
Machine Reset, Remote Button (Optional)
Isolation Relay (*)
brown/green
1029
SPARE (Prior to 9/2015, Remote E-stop)
Isolation Relay (*)
white/yellow 1030
Rear Obstacle Avoidance (Optional) (From Tunnel Controller Output) Isolation Relay (*)
yellow/brown 1031
MCR (Master Control Rly) Monitor
(*) NOTE : Isolation Relay Coils are 24VDC. Other voltages available upon request.
INPUTS, 360-t Tunnel
PLC Inputs are 24VDC(+)