OPERATION
3
page 3.4
RCP–48X
Operations
Section 3
Breakaway Statusing
LED Illuminated Solid (not blinking) - The current status matches the source assigned to the Data
Key for the highest priority level selected (level 1 is highest priority) and the source(s) assigned to
the Data Key for other levels selected either match the current status or are not configured.
LED Blinking - The current status matches the source assigned to the Data Key for the highest
priority level selected (level 1 is the highest priority) but the source(s) assigned to the Data Key for at
least one other selected level does not match the current status.
No LED Illuminated - The current status does not match the source assigned to any Data Key on
the highest priority level selected (level 1 is the highest priority).
STATUSING:
Status by Group Status
LED Illuminated Solid (not blinking) - The current status matches the source(s) assigned to the
Data Key.
LED Blinking - The current status matches the source(s) assigned to the Data Key on some, but
not all, levels.
No LED Illuminated - The current status does not match the source(s) assigned to any Data Key.
Status by Default Status Level
LED Illuminated Solid (not blinking) - The current status matches the source assigned to the Data
Key for the default status level and the source(s) assigned to the Data Key for other levels either
match the status on the default status level or are not configured.
LED Blinking - The current status matches the source assigned to the Data Key for the default
status level and the source(s) assigned to the Data Key for at least one other level does not match
the status on the default status level.
No LED Illuminated - The current status does not match the source assigned to any Data Key on
the default status level.
NOTE: If the destination group being controlled by the panel matches a Destination Data Key, the
Destination Data Key's LED will be illuminated.