Section 2
INSTALLATION
2
page 2.4
RCP-48X
Installation
Figure 2–4 Wiring the Control Panel Connector
Should an additional control panel be added to your system, it will be
necessary to wire the connector using shielded twisted pair cable and a 3-
pin MTA connector. See Figure 2–4.
1. Remove approximately 1 1/2" of insulating jacket from each of the two
wires.
2. Remove approximately 1/2" of wire insulation from the black and red
wires.
3. Twist together and insert the two black wire ends into positon 1.
Crimp down using a screw driver.
4. Twist together and insert the two shield wires into position 2. Crimp
down using a screwdriver.
5. Twist together and insert the two red wire ends into position 3.
Crimp down using a screwdriver.
2.6 Wiring the Control Panel Connector