7
DRIVE UNIT SETTINGS
7.1
Function display
The LEDs (Light Emitting Diodes) are on the circuit board and are visible through the
transparent cover (see picture 2, chapter 7.2).
The perma STAR CONTROL TIME has a red and green LED. The following signals
about operating conditions/malfunctions are displayed by the LED for the user:
7.2
Circuit board settings
The 4-way code switch is located on the circuit board.
Dip switches 1+2 marked “TIME” are used to set the dicharge amount, dip switches
3+4 marked “VOL” are used to set the LC unit size.
You may set/change the switches with the help of a small screw driver or with your
fingers.
LED
Signal
Meaning
green
steady
System functions OK
red
steady for less than 30 seconds with
motor run
STAR CONTROL TIME
is discharging
red
steady signal for more
than 30 seconds
Malfunction/Error
green and red
steady signal
LC unit empty, please change
Picture 2
LED red
LED green
Four-way
code switch
Four-way code switch
with switches 1-4
Plug connection
Circuit board
{
{
TIME VOL
Vol.
Time
3 4
1 2