background image

Operation manual 

16 

2.  Drill the holes for anchor bolt sleeves for fixing of the turnstile housing (see Fig. 10). 
3.  If you lay the cables under the floor surface, prepare the electric raceway to the cables laying 

zone of the turnstile housing (see Fig. 10). 

4.  Insert the sleeves for the anchor bolts into the holes so that they do not stick out above the 

floor surface.

  

5.  Mount the turnstile housing and fix it with the

 

M10 anchor bolts. 

To get an access to the mounting holes of the turnstile housing base remove the  turnstile 

cover (3) and both outer panels (2). Thus,  you get an access to the mounting holes of the 

turnstile housing base.

 

Fix the turnstile housing after laying the cables in the electric raceway 

and inside the turnstile housing. 

 

Fig.10 Hole pattern for the turnstile housing mounting 

6.  The cables layout inside the turnstile housing is shown in Fig. 11. 
7.  Install the turnstile power supply in its place (installation procedure  for  the turnstile power 

supply is given in the power supply certificate). 

8.  Connect the power cable (10) of the turnstile power supply to the CLB “XT3” connector block. 

Connect the RC-panel (9) cable to the CLB “XT1.L” connector block. Connect all the other 

devices’ cables to the corresponding CLB connector blocks (see Fig. 4 and 13).  

9.  When you connect the emergency unblocking device, remove the jumper wire set between the 

contacts Fire Alarm and GND of the CLB “XT1.L” (In) connector block. 

10.  If the turnstile is used in the potential mode, remove the jumper from the "J1" connector (see 

Fig. 4). 

11.  Check serviceability and accuracy of all the electrical connections. Fasten all the cables using 

self-adhesive wires retainers and fixed brace rods included in the delivery set. After all the 

cable connections and the turnstile housing fixing to the floor put the outer panels (2) and the 

turnstile cover (3) back into their places in the reverse order to the dismantling procedure. 

12.  To mount the turnstile cover (3) install it so that the middle strip on its under side is placed on 

the side of turnstile cover lock (6). Connect the indication cables mounted inside the turnstile 

housing to the indication module (4) connectors, after carefully install the turnstile cover on the 

frame. At that the cross angle sections on the turnstile cover should be maximum close to 

relative plug-in guides in the frame. Adjust the turnstile cover by moving it from right to left 

against stop and after fix it by the turnstile cover lock. The turnstile cover lock is closed without 

key by pushing it. 

13.  To mount the barrier arms into the run position, remove the cover from the hub (7) unscrewing 

the screw. Unscrew the fixing bolt on the barrier arm (5). Fit the barrier arm into the mounting 

hole on the hub and fasten it with the bolt. Put a spring washer under the bolt head. The bolts 

must be tightened so as to provide reliable fixation of the barrier arms without a gap.  
Repeat the above-described procedure for fitting up the remaining barrier arms.  
Put the cover onto the hub and fix it with the screw. 

Summary of Contents for TTD-03.1

Page 1: ...OPERATION MANUAL TTD 03 1 Electromechanical Box Tripod Turnstile...

Page 2: ...Electromechanical Box Tripod Turnstile TTD 03 1 Operation Manual...

Page 3: ...ices connectable to the turnstile 12 5 5 Operation contingencies and response 13 6 MARKING AND PACKAGING 13 7 SAFETY REQUIREMENTS 14 7 1 Installation safety requirements 14 7 2 Operation safety requir...

Page 4: ...ion into the product is carried out by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access c...

Page 5: ...ools Self adhesive wires retainer 2 Fixed brace rod 100 mm 2 Operational documentation Certificate 1 Operation manual 1 Packaging Box 1 for turnstile housing 1 Box 2 for turnstile housing cover 1 4 2...

Page 6: ...indicators application not more than 42 V The turnstile has low power consumption not more than 8 5 W The turnstile has galvanic decoupling of outputs Several lined up turnstiles form passageways with...

Page 7: ...sktop device with a shock proof ABS plastic case and is intended for setting and indicating operating modes when the turnstile is operated manually The RC panel overall view is shown in Fig 3 There ar...

Page 8: ...nnects to RC panel ACS controller outputs WRC device intrusion detector emergency unlocking device Fire Alarm External devices are connected in accordance with the turnstile electrical connection layo...

Page 9: ...arm and relays the signal of the current status of the intruder detector Det Out The turnstile is operated by input of a low level signal to the XT1 L connector block contacts Unlock A Unlock B and St...

Page 10: ...l Box Tripod Turnstile 9 Fig 5 Control elements of an external device a normally open relay contact Fig 6 ACS control element circuit with open collector output Fig 7 Output cascades for PASS A PASS B...

Page 11: ...the duration of controlling signal The pulse control mode is intended for the turnstile control with the RC panel WRC and ACS controller outputs of which support the pulse control mode Standard contro...

Page 12: ...he left side outer panel 2 see Fig 4 5 3 1 Operation with the RC panel When the buttons on the RC panel are pressed the STOP button and the two other buttons corresponding to the passage directions co...

Page 13: ...ctor Note Only the manufacturer should carry out the installation of the intrusion detector on the turnstile housing If the turnstile is blocked Always locked mode or Both directions closed one see Ta...

Page 14: ...the barrier arms reset into initial state the both optical sensors become normalized and the output contacts Ready and Common get closed finish of the signal In case of delay of an authorized passage...

Page 15: ...nstile under conditions that do not comply with the requirements of Chapter 2 of this Manual Do not use the turnstile at supply voltage that does not comply with the requirements of Chapter 3 of this...

Page 16: ...measurement accuracy 8 3 Cable length The maximum allowed length of the RC panel WRC ACS controller cable is not more than 50m The maximum allowed length of the turnstile power supply cable depends on...

Page 17: ...nector block 10 If the turnstile is used in the potential mode remove the jumper from the J1 connector see Fig 4 11 Check serviceability and accuracy of all the electrical connections Fasten all the c...

Page 18: ...indication cable 5 CLB 6 control mechanism 7 intrusion detector 8 siren 4 6 9 11 see Fig 13 14 Control the turnstile housing and barrier arms fastening check serviceability and accuracy of all the ele...

Page 19: ...by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access cards readers of are not included in...

Page 20: ...TTD 03 1 Electromechanical Box Tripod Turnstile 19 8 1 Connection layout Fig 13 Connection layout...

Page 21: ...rms turnstile housing and indication modules so as to prevent their mechanical deformation 9 1 Power up 1 Make sure of the accuracy of all the connections and of the power supply cable operability see...

Page 22: ...to the chosen passage direction simultaneously The green indicator above the button of the chosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pict...

Page 23: ...hosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pictogram from the opposite side are on If by the moment of passing through the turnstile the lo...

Page 24: ...are listed in Table 5 Table 4 Possible faults and remedy Fault Possible cause Remedy At the power up the turnstile won t work and there is no light indication on the turnstile housing and the RC pane...

Page 25: ...bricate the friction units of the resetting device with the machine oil four bushes of the resetting device two on the rotation axis of the pusher two on the fastening axis of the springs see Fig 15 h...

Page 26: ...vered by means of transportation with covering facilities railroad cars covered truck car bodies vessel holds and by air transport It is not allowed to stockpile the boxes with the turnstile housings...

Page 27: ...f its receipt the status of passage direction B was Always free Single passage in both directions open for single passage of one person at a time in each direction Active front is at contact Unlock A...

Page 28: ...s open open for passage in direction There is a low level at contact Unlock while there is a high level at contacts Stop and Unlock At this command direction B opens up to the elimination of low level...

Page 29: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 30: ...www perco com...

Reviews: