Operation manual 

14 

surface. The sticker corresponds to Fig.4. To get access to it, remove the turnstile cover (3). Undo 

two M6 nuts, fixing the upper parts of the left-side outer panel (2). Lift the outer panel and take it off 

carefully. 
The outer panel and the turnstile cover mounting is carried out in the reverse order. 
The turnstile in the delivery set (see Clause 4.1) is packed in two boxes, which keep it undamaged 

during the transportation and storage.  
Box 1(for packaging of the turnstile housing) overall dimensions  ...........................  122×38×112 cm 

Box 2 (for packaging of the turnstile cover) overall dimensions  ................................  114×35×13 cm 

Weight (gross)  ..................................................................................................  no more than 89 kg 

7  SAFETY REQUIREMENTS 

7.1  Installation safety requirements 

The installation should be only carried out by the qualified personnel after the careful study of this 

Manual. 

 

Caution! 

 All the cables

 

should be connected up when the power supply is switched off from the AC 

mains. 

 Use only the serviceable tools for installation. 

 Observe general electrical safety rules when laying out the cables. 

See certificates of the power supply units for the safety requirements to those power supply units. 

7.2  Operation safety requirements 

Observe general electrical safety rules when operating the turnstile. 

 

Do not use! 

 Do not use the turnstile under conditions that do not comply  with the requirements of 

Chapter 2 of this Manual. 

 Do not use the turnstile at supply voltage that does not comply with the requirements of 

Chapter 3 of this Manual. 

See certificates of the power supply units for the safety requirements to those power supply units. 

8  INSTALLATION INSTRUCTIONS 

8.1  Installation details 

It is recommended: 

  to mount the turnstile on steady and level concrete (grade 400 or higher, strength group V22.5), 

stone or similar foundations at least 150mm thick; 

  to level the foundation so that the anchoring points of the turnstile lie in the same plane (to be 

verified with a builder’s level); 

  to apply reinforcing elements (400×400×400 mm) for installation on less steady foundation; 

  to organize the passage zone according Fig. 9; 

  to mark the mounting holes according to Fig. 10; 

  to control the vertical position of the turnstile during installation with a plumb line; 

  to carry out installation by means of not less than two people which possess qualifications of 

skilled electrician and installer. 

 

Note: 

When creating the passage area through the turnstile take into account 

 

that the resetting device operates as follows: 

-  at the barrier arm turning at the angle of more than 60° the reset to home position is 

effected in the direction of movement; 

- at the barrier arm turning at the angle less than 60° the reset to home position is effected 

in the counter to the movement direction (reset to home position) 

Summary of Contents for TTD-03.1

Page 1: ...OPERATION MANUAL TTD 03 1 Electromechanical Box Tripod Turnstile...

Page 2: ...Electromechanical Box Tripod Turnstile TTD 03 1 Operation Manual...

Page 3: ...ices connectable to the turnstile 12 5 5 Operation contingencies and response 13 6 MARKING AND PACKAGING 13 7 SAFETY REQUIREMENTS 14 7 1 Installation safety requirements 14 7 2 Operation safety requir...

Page 4: ...ion into the product is carried out by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access c...

Page 5: ...ools Self adhesive wires retainer 2 Fixed brace rod 100 mm 2 Operational documentation Certificate 1 Operation manual 1 Packaging Box 1 for turnstile housing 1 Box 2 for turnstile housing cover 1 4 2...

Page 6: ...indicators application not more than 42 V The turnstile has low power consumption not more than 8 5 W The turnstile has galvanic decoupling of outputs Several lined up turnstiles form passageways with...

Page 7: ...sktop device with a shock proof ABS plastic case and is intended for setting and indicating operating modes when the turnstile is operated manually The RC panel overall view is shown in Fig 3 There ar...

Page 8: ...nnects to RC panel ACS controller outputs WRC device intrusion detector emergency unlocking device Fire Alarm External devices are connected in accordance with the turnstile electrical connection layo...

Page 9: ...arm and relays the signal of the current status of the intruder detector Det Out The turnstile is operated by input of a low level signal to the XT1 L connector block contacts Unlock A Unlock B and St...

Page 10: ...l Box Tripod Turnstile 9 Fig 5 Control elements of an external device a normally open relay contact Fig 6 ACS control element circuit with open collector output Fig 7 Output cascades for PASS A PASS B...

Page 11: ...the duration of controlling signal The pulse control mode is intended for the turnstile control with the RC panel WRC and ACS controller outputs of which support the pulse control mode Standard contro...

Page 12: ...he left side outer panel 2 see Fig 4 5 3 1 Operation with the RC panel When the buttons on the RC panel are pressed the STOP button and the two other buttons corresponding to the passage directions co...

Page 13: ...ctor Note Only the manufacturer should carry out the installation of the intrusion detector on the turnstile housing If the turnstile is blocked Always locked mode or Both directions closed one see Ta...

Page 14: ...the barrier arms reset into initial state the both optical sensors become normalized and the output contacts Ready and Common get closed finish of the signal In case of delay of an authorized passage...

Page 15: ...nstile under conditions that do not comply with the requirements of Chapter 2 of this Manual Do not use the turnstile at supply voltage that does not comply with the requirements of Chapter 3 of this...

Page 16: ...measurement accuracy 8 3 Cable length The maximum allowed length of the RC panel WRC ACS controller cable is not more than 50m The maximum allowed length of the turnstile power supply cable depends on...

Page 17: ...nector block 10 If the turnstile is used in the potential mode remove the jumper from the J1 connector see Fig 4 11 Check serviceability and accuracy of all the electrical connections Fasten all the c...

Page 18: ...indication cable 5 CLB 6 control mechanism 7 intrusion detector 8 siren 4 6 9 11 see Fig 13 14 Control the turnstile housing and barrier arms fastening check serviceability and accuracy of all the ele...

Page 19: ...by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access cards readers of are not included in...

Page 20: ...TTD 03 1 Electromechanical Box Tripod Turnstile 19 8 1 Connection layout Fig 13 Connection layout...

Page 21: ...rms turnstile housing and indication modules so as to prevent their mechanical deformation 9 1 Power up 1 Make sure of the accuracy of all the connections and of the power supply cable operability see...

Page 22: ...to the chosen passage direction simultaneously The green indicator above the button of the chosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pict...

Page 23: ...hosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pictogram from the opposite side are on If by the moment of passing through the turnstile the lo...

Page 24: ...are listed in Table 5 Table 4 Possible faults and remedy Fault Possible cause Remedy At the power up the turnstile won t work and there is no light indication on the turnstile housing and the RC pane...

Page 25: ...bricate the friction units of the resetting device with the machine oil four bushes of the resetting device two on the rotation axis of the pusher two on the fastening axis of the springs see Fig 15 h...

Page 26: ...vered by means of transportation with covering facilities railroad cars covered truck car bodies vessel holds and by air transport It is not allowed to stockpile the boxes with the turnstile housings...

Page 27: ...f its receipt the status of passage direction B was Always free Single passage in both directions open for single passage of one person at a time in each direction Active front is at contact Unlock A...

Page 28: ...s open open for passage in direction There is a low level at contact Unlock while there is a high level at contacts Stop and Unlock At this command direction B opens up to the elimination of low level...

Page 29: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 30: ...www perco com...

Reviews: