background image

TTD-03.1 Electromechanical Box Tripod Turnstile 

21 

Table 2 Pulse control mode (the jumper is set on the connector J1) 

 

 

 

The turnstile 

operating modes   Actions to do  

Indication 

on the RC  

Indication on the 

turnstile  

Response  

to the barrier arm 

turning 

Always locked 

(Closed for entry 

and exit) 

Press the 

STOP

 

button on the RC  

The red 

indicator 

above the 

STOP 

button is on  

The two “Red 

cross” pictograms 

(left and right) are 

on  

 

Single passage in 

the set direction 

(open for passage 

of one person in 

the chosen 

direction)  

Press the button 

on the RC 

corresponding to 

the chosen 

passage 

direction  

The green 

indicator 

above the 

button of the 

chosen 

passage 

direction is 

on  

The “Green arrow” 

pictogram, 

showing the 

passage direction, 

and the “Red 

cross” pictogram 

from the opposite 

side are on  

Turnstile gets blocked 

Bidirectional single 

passage (open for 

one-by-one person 

passage in each 

direction)  

Press both the 

left and right side 

buttons on the 

RC 

simultaneously  

The two 

green 

indicators 

(left and 

right) are on 

The two “Green 

arrow” pictograms 

(left and right) are 

on 

Turnstile gets blocked 

for passage in that 

direction 

Free passage in 

the set direction 

(open for free 

passage in the 

chosen direction) 

Press the 

STOP

 

button and the 

button 

corresponding to 

the chosen 

passage 

direction 

simultaneously  

The green 

indicator 

above the 

button of the 

chosen 

passage 

direction is 

on  

The “Green arrow” 

pictogram, 

showing the 

passage direction, 

and the “Red 

cross” pictogram 

from the opposite 

side are on  

Turnstile remains open 

in the set direction 

Free passage in 

the set direction 

and single passage 

in the opposite 

direction (open for 

free passage in the 

chosen direction 

and for a person’s 

passage in the 

opposite direction)  

Carry out actions 

stated in 

Chapters 2 and 

4 of the present 

table in any 

order  

The two 

green 

indicators 

(left and 

right) are on 

The two “Green 

arrow” pictograms 

(left and right) are 

on 

After the passage in the 

free passage direction 

the turnstile remains 

open in both directions. 

After the passage in the 

single passage direction 

the turnstile remains 

open in the free passage 

direction but it is gets 

blocked in the single 

passage direction  

6  Always free (open 

for entry and exit). 

Press all the 3 

buttons on the 

RC 

simultaneously 

The two 

green 

indicators 

(left and 

right) are on  

The two “Green 

arrow” pictograms 

(left and right) are 

on  

Turnstile remains open 

 

Note:

 

Pressing the button on the RC-panel corresponds to the low-level signal supply to the 

contacts (“Unlock A”, “Unlock B” and “Stop”) of the “XT1.L” connector block relatively to the 

contact “GND”. 

At the turnstile power supply switching-on the turnstile initial state is closed (the mechanical 

release lock (8) should be locked with the key). 

Summary of Contents for TTD-03.1

Page 1: ...OPERATION MANUAL TTD 03 1 Electromechanical Box Tripod Turnstile...

Page 2: ...Electromechanical Box Tripod Turnstile TTD 03 1 Operation Manual...

Page 3: ...ices connectable to the turnstile 12 5 5 Operation contingencies and response 13 6 MARKING AND PACKAGING 13 7 SAFETY REQUIREMENTS 14 7 1 Installation safety requirements 14 7 2 Operation safety requir...

Page 4: ...ion into the product is carried out by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access c...

Page 5: ...ools Self adhesive wires retainer 2 Fixed brace rod 100 mm 2 Operational documentation Certificate 1 Operation manual 1 Packaging Box 1 for turnstile housing 1 Box 2 for turnstile housing cover 1 4 2...

Page 6: ...indicators application not more than 42 V The turnstile has low power consumption not more than 8 5 W The turnstile has galvanic decoupling of outputs Several lined up turnstiles form passageways with...

Page 7: ...sktop device with a shock proof ABS plastic case and is intended for setting and indicating operating modes when the turnstile is operated manually The RC panel overall view is shown in Fig 3 There ar...

Page 8: ...nnects to RC panel ACS controller outputs WRC device intrusion detector emergency unlocking device Fire Alarm External devices are connected in accordance with the turnstile electrical connection layo...

Page 9: ...arm and relays the signal of the current status of the intruder detector Det Out The turnstile is operated by input of a low level signal to the XT1 L connector block contacts Unlock A Unlock B and St...

Page 10: ...l Box Tripod Turnstile 9 Fig 5 Control elements of an external device a normally open relay contact Fig 6 ACS control element circuit with open collector output Fig 7 Output cascades for PASS A PASS B...

Page 11: ...the duration of controlling signal The pulse control mode is intended for the turnstile control with the RC panel WRC and ACS controller outputs of which support the pulse control mode Standard contro...

Page 12: ...he left side outer panel 2 see Fig 4 5 3 1 Operation with the RC panel When the buttons on the RC panel are pressed the STOP button and the two other buttons corresponding to the passage directions co...

Page 13: ...ctor Note Only the manufacturer should carry out the installation of the intrusion detector on the turnstile housing If the turnstile is blocked Always locked mode or Both directions closed one see Ta...

Page 14: ...the barrier arms reset into initial state the both optical sensors become normalized and the output contacts Ready and Common get closed finish of the signal In case of delay of an authorized passage...

Page 15: ...nstile under conditions that do not comply with the requirements of Chapter 2 of this Manual Do not use the turnstile at supply voltage that does not comply with the requirements of Chapter 3 of this...

Page 16: ...measurement accuracy 8 3 Cable length The maximum allowed length of the RC panel WRC ACS controller cable is not more than 50m The maximum allowed length of the turnstile power supply cable depends on...

Page 17: ...nector block 10 If the turnstile is used in the potential mode remove the jumper from the J1 connector see Fig 4 11 Check serviceability and accuracy of all the electrical connections Fasten all the c...

Page 18: ...indication cable 5 CLB 6 control mechanism 7 intrusion detector 8 siren 4 6 9 11 see Fig 13 14 Control the turnstile housing and barrier arms fastening check serviceability and accuracy of all the ele...

Page 19: ...by the customer installer in accordance with the design of the pass through and the characteristics of the access control system and the control controller Access cards readers of are not included in...

Page 20: ...TTD 03 1 Electromechanical Box Tripod Turnstile 19 8 1 Connection layout Fig 13 Connection layout...

Page 21: ...rms turnstile housing and indication modules so as to prevent their mechanical deformation 9 1 Power up 1 Make sure of the accuracy of all the connections and of the power supply cable operability see...

Page 22: ...to the chosen passage direction simultaneously The green indicator above the button of the chosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pict...

Page 23: ...hosen passage direction is on The Green arrow pictogram showing the passage direction and the Red cross pictogram from the opposite side are on If by the moment of passing through the turnstile the lo...

Page 24: ...are listed in Table 5 Table 4 Possible faults and remedy Fault Possible cause Remedy At the power up the turnstile won t work and there is no light indication on the turnstile housing and the RC pane...

Page 25: ...bricate the friction units of the resetting device with the machine oil four bushes of the resetting device two on the rotation axis of the pusher two on the fastening axis of the springs see Fig 15 h...

Page 26: ...vered by means of transportation with covering facilities railroad cars covered truck car bodies vessel holds and by air transport It is not allowed to stockpile the boxes with the turnstile housings...

Page 27: ...f its receipt the status of passage direction B was Always free Single passage in both directions open for single passage of one person at a time in each direction Active front is at contact Unlock A...

Page 28: ...s open open for passage in direction There is a low level at contact Unlock while there is a high level at contacts Stop and Unlock At this command direction B opens up to the elimination of low level...

Page 29: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 30: ...www perco com...

Reviews: