![Pepperl+Fuchs IC-KP-B7-V95 Manual Download Page 85](http://html.mh-extra.com/html/pepperl-fuchs/ic-kp-b7-v95/ic-kp-b7-v95_manual_1527931085.webp)
Appendix A
20
13
-0
4
85
A command confirmation appears in the input field:
2
Byte 8
Command code
10h
Command
SR
(Single read double words)
Byte 9
Number of double words/
Channel/Toggle bit
10h
1 double word = 4 bytes
Element defines the channel.
Toggle bit = 0
Byte 10
Address of double word
(high byte)
00h
Start address = 0
Byte 11
Address of double word
(low byte)
00h
Start address = 0
byte 12
00h
Byte 13
00h
Byte 14
00h
Byte 15
00h
3
Byte 16
...
Byte 23
00h
No commands are
transmitted to channel 3.
4
Byte 24
...
Byte 31
00h
No commands are
transmitted to channel 4.
Ele-
ment
Implicit
telegram
Use
Con-
tents
Description
1
Byte 0
Command code
10h
Command
SR
(Single read words)
Byte 1
Number of double words/
Channel/Toggle bit
12h
1 double word = 4 bytes
Channel = element = 1
Toggle bit = 0
Byte 2
Status
FFh
Processing command.
Byte 3
Reply counter
05h
For every IDENT telegram,
the value on the reply counter
increases by 1.
Byte 4
-
00h
Byte 5
-
00h
Byte 6
-
00h
Byte 7
-
00h
Ele-
ment
Implicit
telegram
Use
Con-
tents
Description