Commissioning
Non-volatile parameters
Volatile parameters
Configure the read/write station with the described system commands. "99" is
preset as the tag type.
Parameter
Default setting
Value range
General
LCD contrast
50
36 ... 71
LCD light
On
On / off
Language
English
English / German
Multiplex mode
off
On / off
R/W head
Trigger mode
off
On / off
Tag type
99
00 ... FF
DeviceNet interface
Network address
63d
00d ... 63d
Baud rate
125 kBit/s
125 kBit/s, 250 kBit/s,
500 kBit/s
Instance Out
100d
100d ... 112d
Instance In
150d
150d ... 162d
Data hold time
10 x 10 ms
000 x 10 ms ... 255d x 10
ms
Parameter
Default setting
Value range
R/W head
Password mode
Off
on / off
Password
00000000
00000000 ... FFFFFFFF