30
Commands
Confirmation
Response: Type IPC03 tag is located in front of the read/write head, the
highlighted part depends on the content of the tag
Alternative response: No tag in front of read/write head
7.3
Command types
When using commands, a distinction is always made between the two command
types
single mode
and
enhanced mode
.
Single mode
The command is executed once. A response is issued immediately.
Enhanced mode
The command remains permanently active until it is interrupted by the user or by
an error message. A response is issued immediately.
The command remains active after the response is issued. Data is only
transferred if read/write tags change. Read/write tags are not read twice. If a
read/write tag leaves the read range, the status '5' is output.
10:22:FF:01
10
Repeat command code
SR
(single read words)
22
Number of double words (2) / channel (1), toggle bit
FF
Status FFh (processing command)
01
Reply counter
10:22:00:02:
31:32:33:34:35:36:37:38
10
Repeat command code
SR
(single read words)
22
Number of double words (2) / channel (1), toggle bit
00
Status 0 (command executed without error)
02
Reply counter
31:32:33:34:35:36:37:38 Data
10:02:05:02
10
Repeat command code
SR
(single read words)
02
Number of double words (0) / channel (1), toggle bit
05
Status 5 (no tag in the detection range)
02
Reply counter