Commands
Setting "Default Read"
1. Activate the password mode.
2. Write the read range start and end into the "Control Word".
3. Deactivate the password mode.
4. Read the data range with address designation 0000h and word count 0h.
IPC03 configuration
Single get configuration (SG):
Response:
The R/W head makes exactly one attempt to read a word in the configuration
range ("Protection Word" or "Control Word") from the address <ConfAddr>.
Byte
Contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Command code (61h)
0
1
1
0
0
0
0
1
Byte 1
Reserved/Ident channel/Toggle bit
0
0
0
0
<Channel>
<T>
Byte 2
Reserved
0
0
0
0
0
0
0
0
Byte 3
Address in the configuration range
<ConfAddr>
Byte
Contents
Bit no.
7
6
5
4
3
2
1
0
Byte 0
Command code (61h)
0
1
1
0
0
0
0
1
Byte 1
Reserved/Ident channel/Toggle bit
0
0
0
0
<Channel>
<T>
Byte 2
Status
<Status>
Byte 3
Reply counter
<ReplyCounter>
Byte 4
Data 00h ... FFh
<Data>
Byte 5
Data 00h ... FFh
<Data>
Byte 6
Data 00h ... FFh
<Data>
Byte 7
Data 00h ... FFh
<Data>