Par

t No

. 51

2083  Dra

wing No

. 1

29-0205a  03/09

Getting Started

Typical Single Protected Enclosure Connections

HELPFUL HINTS

If flammable gases are lighter than air, the inlet connection 

to each enclosure must enter near a bottom corner. The 

outlet connection, for an optional enclosure protection 

vent or piping to an adjacent protected enclosure, must 

exit near an extreme opposite top corner.
If flammable gases are heavier than air, inlet and outlet 

connections must be reversed.
In all cases, the most prevalent gas must determine the 

location of inlet and outlet connections.

Determining Enclosure Inlet & Outlet Connection Locations

HELPFUL HINTS

To ensure adequate protective gas flow to the protected enclosure(s), all piping and tubing must be fully reamed.
Precautions must be taken to prevent crimping and other damage to protective gas piping and tubing.
When protecting multiple enclosures with a single enclosure protection system, the enclosures must be 

connected in series from the smallest to the largest to ensure adequate protective gas flow.

PROTECTED 

ENCLOSURE

C

B

ENCLOSURE PROTECTION VENT

(Optional)

E

SUPPLY

REFERENCE

1/2" 

PROTECTIVE 

GAS SUPPLY 

HEADER

ENCLOSURE 

PROTECTION 

SYSTEM

Maximum tubing / pipe pength and 

maximum number of bends / elbows

1/4" O.D. tubing 

fully reamed

20 feet

10 bends

1/4" O.D. tubing 

fully reamed

Description

*Tubing or pipe diameter

Enclosure 

supply

System 

supply tubing

Enclosure 

reference

1/4" O.D. tubing 

fully reamed

5 feet

5 bends

20 feet

10 bends

Multi - enclosure 

connections 

1/2" I.D. pipe 

fully reamed

10 feet

5 elbows

Optional remote 

venting 

1/2" I.D. pipe 

fully reamed

30 feet

5 elbows

A

B

E

D

C

ENCLOSURE 

PROTECTION 

SYSTEM

PROTECTED 

ENCLOSURE

PROTECTED 

ENCLOSURE

D

SUPPLY

REFERENCE

B

TYPICAL MULTIPLE PROTECTED ENCLOSURE CONNECTIONS

1/2" 

PROTECTIVE 

GAS SUPPLY 

HEADER

A

A

D

C

PROTECTED 

ENCLOSURE

*NOTE: Tube and pipe sizes are not equal in inside diameters.

 DO NOT substitute tube for pipe with same trade size. 

INLET

INLET

Connections for heavier than 

air gases and vapors

OUTLET

OUTLET

Connections for lighter than 

air gases and vapors

Summary of Contents for 1011 Series

Page 1: ...MODEL 1011 TYPE Z PURGE PRESSURIZATION SYSTEM PROCESS AUTOMATION INSTALLATION AND OPERATION MANUAL...

Page 2: ...ive heat utilize combustible gas or expose arcing contacts to the hazardous atmosphere in Type 4 or 12 enclosures in the place of explosion proof Type 7 enclosures Other purposes include heat moisture...

Page 3: ...closure pressure control regulator 513315 002000 1 Installation operation manual 129 0205 1 Enclosure warning nameplate CI 513008 EWN 1 1 Enclosure warning nameplate CII 513009 EWN 2 Please call and r...

Page 4: ...erials such as materials designed to meet or exceed ANSI UL94 ratings of 94 V 0 or 94 5V Adjacent Enclosures 1 Adjacent enclosures must be protected by one of the following means a purged or pressuriz...

Page 5: ...verview PROTECTIVE GAS SUPPLY SYSTEM SUPPLY TUBING ELECTRICAL ALARM WIRING CONDUIT SEAL SERVICE VALVE SYSTEM SUPPLY FITTING ENCLOSURE PROTECTION SYSTEM SYSTEM MOUNTING BOLT ENCLOSURE SUPPLY TUBING ENC...

Page 6: ...ure protection system the enclosures must be connected in series from the smallest to the largest to ensure adequate protective gas flow PROTECTED ENCLOSURE C B ENCLOSURE PROTECTION VENT Optional E SU...

Page 7: ...nded surface 4 Check for obstructions hindering bolt fastening drill and ream the mounting holes before mounting the system 5 Secure the system to the enclosure or other mounting surface using the fas...

Page 8: ...8 8 25 8 8 25 8 8 Panel Cutout 7 Panel Cutout 7 3 25 1 25 6875 7 3125 8 875 2 4375 25 O D TYP 2 System Mounting Plate 8 25 8 1011 LH Left hand configuration 1011 RH Right hand configuration 1011 TM To...

Page 9: ...inent position on or near all enclosure accesses doors and covers One 1 EWN is provided with each system located in the manila envelope taped to the mounting flange of the system Additional EWNs are a...

Page 10: ...LOSURE CONNECTION FITTING Pneumatic Connection Requirements ALL FITTINGS MAY BE CUSTOMER OR FACTORY FURNISHED 1 For system supply one 1 SC 4 1 4 male straight connector or one 1 NC 4 1 4 male elbow co...

Page 11: ...tting manufacturer s specifications Secure tubing to appropriate structural supports as required Tubing PM Configurations Enclosure bulkhead fittings 1 Select the fittings required to install the syst...

Page 12: ...ce Supply Enclosure reference bulkhead fitting Enclosure supply bulkhead fitting Enclosure pressure gauge Enclosure reference inlet Venturi orifice Mounting bracket System supply inlet Enclosure press...

Page 13: ...larm and the enclosure IMPORTANT NOTE NFPA 496 requires the use of an alarm or an indicator to detect the loss of safe enclosure pressure In addition the NFPA 496 requires that if an indicator alone i...

Page 14: ...rators withhold power to the enclosure while inducing Class I exchange for at least five 5 minutes Normal exchange time calculations should be doubled if large obstructions block inert gas flow The st...

Page 15: ...f protected equipment power 6 Excessively hot equipment must be isolated in a separate protected enclosure unless the enclosure is marked with a warning which indicates a required cool down time perio...

Page 16: ...drifts up or down from the safe pressure setting Application involves a small tightly sealed enclosure and or a fluctuating protective gas supply Pre regulate the protective gas supply upstream of the...

Page 17: ...MITED WARRANTY SET FORTH HEREIN IS THE ONLY WARRANTY MADE BY P F WITH RESPECT TO THE PRODUCTS IT IS EXPRESSLY AGREED AND UNDERSTOOD THAT P F MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTI...

Page 18: ...properly then carefully readjust system according to the set up procedure and operating sequence on pages 14 and 15 Replace or tighten stem packing nut as required to prohibit stem packing leakage Ca...

Page 19: ..._________________________________________________________ Notes _ _______________________________________________________________________________________________ ______________________________________...

Page 20: ...ost demanding needs of industry Resulting from our world wide presence and our high flexibility in production and customer service we are able to offer complete individual solutions wherever and whene...

Reviews: