Arctica 3200xlp switch Installation Guide Chapter 1 Introduction
4
and telnet configuration through this port.
The console port supports asynchronous mode, set the data bit as 8, the stop bit as
1, the parity bit as none, the default baud rate as 115200bps.
1.2.2.Back Panel
The back panel of Arctica 3200xlp includes 2 alternating current of 220V power
module (it provides redundancy backups) and 5 fan rabbets.
Fig 1
-
3
Back panel of Arctica 3200xlp
1.3.Status LEDs
The indicator light on front panel of Arctica 3200xlp has 128 QSFP+ port indicator
light, 2 power supply indicator light and system automatic diagnoses LED. They are
shown below and described in the following table.
Table 1
-
2 The explanation of indicator light of front panel
Indicator light
Front Panel
sign
State
Meanings
Power supply
indicator light
P-1/P-2
Green light
always on
Power supply module move
normally.
Put out
No power supply or make a
mistake.
System status
indicate LED
START
Green light
always on
The system is power on and
running normally.
Put out
The system is power off.
Table 1
-
3 The explanation of indicator light of rear panel
Indicator light
Rear Panel sign
State
Meanings
Fan module
indicator light
FAN1/FAN2/FA
N3/FAN4/FAN5
Green light
always on
Fan module move normally.
Red light always
on
No fan module or fan speed is 0
Put out
Fan module is power off