Arctica 3200xlp switch Installation Guide       Chapter 2 Installation Notice

 

1

 

2. Installation  Notice 

To ensure the proper operation of Arctica 3200xlp and your physical security, please 

read carefully the following installation guide. 

2.1.Environmental Requirements  

 

The switch must be installed in a clean area. Otherwise, the switch may be damaged 
by electrostatic adherence. 

  Maintain the temperature@airflow front to back within 0 to 45 °C, 

temperature@airflow back to front with 0 to 40°C and the humidity within 10% to 
90%, non-condensing. 

 

The switch must be put in a dry and cool place. Leave sufficient spacing around the 
switch for good air circulation. 

 

The switch must work in the range of AC power input: 100 ~ 

240VAC

 (

50/60Hz)

 

The switch must be well grounded in order to avoid ESD damage and physical injury 
of people. 

 

The switch should avoid the sunlight perpendicular incidence. Keep the switch away 
from heat sources and strong electromagnetic interference sources.  

  The switch must be mounted to a standard 19’’ rack or placed on a clean level 

desktop. 

2.1.1.Dust and Particles 

 

Dust is harmful to the safe operation of Arctica 3200xlp. Dust can lead to 

electrostatic adherence, especially likely under low relative humidity, causing poor 

contact of metal connectors or contacts. Electrostatic adherence will result in not only 

reduced product lifespan, but also increased chance of communication failures. The 

recommended value for dust content and particle diameter in the site is shown below: 

 

Max Diameter (µm) 

0.5

1

3

Max Density 

(particles/m³) 

1.4×10

5

 7×10

5

 2.4×10

5

 1.3×10

5

 

 

Table 2

-

1 Environmental Requirements: Dust 

 

 

In addition, salt, acid and sulfide in the air are also harmful to the switch. Such 

harmful gases will aggravate metal corrosion and the aging of some parts. The site 

should avoid harmful gases, such as SO

2

, H

2

S, NO

2

, NH

3

 and Cl

2

, etc. The table below 

details the threshold value. 

Summary of Contents for Arctica 3200xlp Series

Page 1: ...Arctica 3200xlp switch Installation Guide Content 1 Arctica 3200xlp Series switch Installation Guide Version 1 1 2017 02 07...

Page 2: ...tal Requirements 1 2 1 1 Dust and Particles 1 2 1 2 Temperature and Humidity 2 2 1 3 Power Supply 3 2 1 4 Preventing Electrostatic Discharge Damage 3 2 1 5 Anti interference 3 2 1 6 Rack Configuration...

Page 3: ...Arctica 3200xlp switch Installation Guide Content 3 3 2 7 AC Power Supply Connection 7 3 2 8 Earthing Cable Connection 8 3 2 9 Checking the Switch 9...

Page 4: ...Gb connecting to 40Gb 10Gb scheme in data center and distripark network with the characteristic of high reliability multiple redundancy high consistency and flexible convergence proportion Arctica 320...

Page 5: ...us policies can be conducted to forward the traffic By implementing ACL policies users can filter the virus packets such as Worm Blaster Worm Sasser and Red Code etc Arctica 3200xlp switch also suppor...

Page 6: ...ovides more help for building the grand IP network Arctica 3200xlp supports LDP function and MPLS VPN it can access the public network and it can be deployed as PE and P 1 2 Description of Hardware 1...

Page 7: ...tor light and system automatic diagnoses LED They are shown below and described in the following table Table 1 2 The explanation of indicator light of front panel Indicator light Front Panel sign Stat...

Page 8: ...onnection or fail to connect Indicator light of QSFP port Green light always on The port is under the connection state of 40G Amber light always on The port is under the connection state of 4x10G Wink...

Page 9: ...3 30AWG 3 0m QSFP to 4Xsfp Cable Amphenol 582410007 30AWG 3 0m QSFP to QSFP Cable Molex 747571051 30AWG 0 5m 747571101 30AWG 1 0m 747571301 30AWG 3 0m 1 5 Power Supply Module 1 5 1 460W Power Module...

Page 10: ...240VAC and the export is 12V 5 There is a fan and a handle for sticking in or pulling out the module on the back of the power supply The power supply module supports the hot plug Caution 460W and 550...

Page 11: ...00xlp Type Attribute Arctica 3200xlp Dimension W H D mm 433 8 44 550 Weight 10 172 kg Fixed Port 32 QSFP ports Management Port 1 RJ 45 serial console port Power Input 100 240VAC 50 60Hz 2 8A 5 6A Syst...

Page 12: ...sunlight perpendicular incidence Keep the switch away from heat sources and strong electromagnetic interference sources The switch must be mounted to a standard 19 rack or placed on a clean level desk...

Page 13: ...r to contract making the fastening screw insecure Furthermore in dry environments static electricity is liable to be produced and cause harm to internal circuits Temperature extremes can cause reduced...

Page 14: ...ut to ensure proper grounding of the power supply system The input source for the switch should be reliable and secure a voltage adaptor can be used if necessary The building s circuit protection syst...

Page 15: ...e stacked closely When mounting devices in an open rack care should be taken to prevent the rack frame from obstructing the switch ventilation openings Be sure to check the positioning of the switch a...

Page 16: ...the tinder near the switch Do not configure the switch alone in a dangerous situation Use standard power sockets which have overload and leakage protection Inspect and maintain the site and the switc...

Page 17: ...inside 3 1 2 Required Tools and Utilities The required tools and utilities are shown below Cross screwdrivers Flat blade screwdriver ESD wrist strap Antistatic uniform Caution Users should prepare th...

Page 18: ...ided Leave enough space around the switch for good air circulation Caution The brackets are used to fix the switch on the rack They can t serve as a bearing Please place a rack shelf under the switch...

Page 19: ...the following approach 1 The golden finger is entad and aim at the power supply rabbet of the machine to insert to the end downwards You can hear the lock sound of click 2 Force the board on the side...

Page 20: ...d and adown and aim at the fan rabbet of the back machine flatly to the end You can hear the lock sound of click 2 Pinch the sheet metal inward and draw the fan module forth when taking out it Caution...

Page 21: ...aracter terminal 3 2 5 QSFP Transceiver Installation Arctica 3200xlp provides 32 QSFP ports The procedure for installing the QSFP transceiver is shown below Step 1 Put on a ESD wrist strap or antistat...

Page 22: ...r bore Remove the protective cap from one end of the fiber cable Keep the fiber end clean and neat Step 2 Attach one end of the fiber cable to the QSFP transceiver and attach the other end to the tran...

Page 23: ...le to QSFP transceiver of Arctica 3200xlp switch 2 Check out the indicator light state of the light port If LINK light is bright it means the link is connection If LINK light puts out it means the lin...

Page 24: ...dicator in the front panel of the switch The corresponding PWR indicator should light Arctica 3200xlp is self adjustable for the input voltage As soon as the input voltage is in the range printed on t...

Page 25: ...ew from accessories put and screw down the fixed nut on the earthing pillar of the switch 3 Connect another side of the earthing cable to the earthing side Caution The unit shall be permanently connec...

Reviews: