SOIL CULTIVATOR CULTIVION
58_80347-P
7. INCIDENTS AND TROUBLESHOOTING
Symptoms
State of the on/off switch of the battery
State of the LEDs
Probable cause
Checks
Solutions
Repairer
0
O
ff
B
at
te
ry
is
o
ff
Battery switch
Flip the bat- tery switch
User
The power
cord is severed
Check the con- dition of the cord
Change the cord
PELLENC autho- rised distributor
Battery
Check that the bat-
tery is not com- pletely discharged
Charge
the battery
User
O
ff
Electronic circuit board
At an authorised PEL-
LENC distributor
Change the elec- tronic board if the
diodes remain off
a
fte
r s
ta
rti
ng
and checking the previous points
PELLENC autho- rised distributor
Trigger no
longer functions
At an authorised PEL-
LENC distributor
Change the trig- ger or sensor
PELLENC autho- rised distributor
The machine does not start
I
On
Electronic circuit board
At an authorised PEL-
LENC distributor
Change the circuit board
PELLENC autho- rised distributor
Tightening of the two working tool head screws
Tighten to 6.0N.m
Tighten to 6.0N.m
The machine makes an un- usual noise
I
On
Tighten screw on working head
Tighten to 12.0N.m
Tighten to 12.0N.m
User
LEDs flash- ing during use
I
Single flash
The machine is close to its temperature limit
LEDs flashing
Reduce the ma- chine speed or pause for a while
User
I
O
ff
The machine has reached its tem-
perature limit
4 beeps from the battery
Let the ma- chine cool for about 5 mins
User
The machine
stops during use
Stop then restart the battery, and see section “The tool does not start” if necessary
30