Flat Bed Foil Printer
User Guide
Peleman Industries
68
c.
Are you using the correct settings? Check selected material. If correctly selected, go
t
o ‘Settings’
->
‘customize’ and check parameters.
d.
Ensure the surface of the ring is clean and straight. Inspect for splinters and remove
if needed.
e.
Add paper ring on right side (item SPUP0000142)
f.
Try to print with another foil. If another foil colour prints better with same settings
on same material, contact your local dealer to request a foil change.
g.
Contact our local representative and include a video of the issue (or a clear problem
description) and the serial number of the machine.
7.3
Troubleshooting
–
Calibration
The position calibration is done in the factory and usually there is no need for new position
calibration. However, when printer is more as 3mm off the correct position a new
calibration may be needed.
Function in ‘Testing
and Calibrati
on’ tab can be
used to test calibration.
a.
Perform calibration te
st. Use build in function in ‘testing and calibration’ tab to first
print a circle and measure the distances. Follow the instructions displayed.
b.
When calibration is passed, plea
se don’t perfo
rm the calibration.
c.
When calibration is needed (clearly more as 3mm off correct position) you can
perform the calibration process. Follow the steps shown is software correctly. Make
sure to enter correct coordinates of the dot.
d.
After the process make a circle test again.
e.
Double check the circle test by closing the software and repowering the machine.
f.
If calibration is still fine
–
the issue is solved.
g.
When printer is again off the correct position repeat the calibration process
described above few more times.
h.
When the issue is still there
–
it is advised to downgrade or update the firmware
(examples: 2.32 to 2.28) and calibrate in lower or higher version. Contact your
distributor for technical assistance in downgrading.