P550c Operation Manual
6 Operating the system
148
You can reset the counter to zero at any time during operation by pressing Panel button 2, see
page 32
Note:
Resetting or varying the distance counter during a survey will render the automatic retrieval
function ineffective as the crawler will return to the new zero position and not the point where the crawler
began the survey.
Sonde
The P550 crawlers feature an integrated, multi-frequency sonde. The Sonde allows you to locate the
crawler’s position using a Radiodetection cable and pipe locator such as an RD5100S or RD7100DL.
You can choose the transmitting frequency in one of two ways:
1 From the home screen, press panel button 3 (see
page 32
) to cycle round the available frequencies
2 Using the
Sonde frequency
item in the
Equipment settings
menu (see
page 110
For more information on locating the sonde and frequency selection, please refer to the documentation
supplied with your cable and pipe locator. The sonde should be used as an estimation tool for assisting
with product location.