background image

 

P550c Operation Manual 

3 System overview 

 

 

www.pearpoint.com

 

25

 

3 System overview 

The flexitrax P550c pipeline video inspection system comprises of a controller, powered cable drum or 
manual cable drum plus PSU, crawler, camera and accessories.  

3.1 Controller 

The P550c controller is the command module, digital video recorder and playback device. Video is 
displayed on a 12.1" (307 mm) high definition, industrial TFT LCD screen. Video, pictures and inspection 
reports are stored on a high-speed, high capacity (128GB) internal solid state storage.  

The P550c controller is compatible with the full range of P550c/P350 drums, crawlers, cameras and 
accessories as well as the full range of P540c/P340 cameras, reels and accessories, providing 
unmatched modularity and inspection capability from 1¼

” (30mm) pipes all the way to 59” (1.5m).  

The P550c controller has an internal, rechargeable lithium-ion battery. A fully charged battery will power 
the controller for around 4 to 6 hours, depending on usage factors such as recording/playing back, 
display brightness etc.  

Summary of Contents for Flexitrax P550c

Page 1: ...flexitrax P550c Operation Manual Pearpoint s advanced crawler based digital video inspection system Operation Manual P550c OPMAN ENG 04 Rev 04 May 2019...

Page 2: ...chasing the appropriate product for your needs The contents of this manual are subject to change Pearpoint products are under continuous development Pearpoint reserves the right to modify any product...

Page 3: ...notice This document may not be copied reproduced transmitted modified or used in whole or in part without the prior written consent of Radiodetection Ltd Other trademarks or registered trademarks men...

Page 4: ...WEEE Directive 2012 19 EU Industry Canada Compliance ICES 003 Class A Notice This Class A digital apparatus complies with Canadian ICES 003 Avis NMB 003 Classe A Cet appareil num rique de la classe A...

Page 5: ...ts are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency e...

Page 6: ...ution Cautions alert you to possible equipment damage Note Notes contain useful information Warning symbols General Warning Refer to the manual for specific instruction or advice Electrical Hazard Obs...

Page 7: ...s it may identify other safety issues Always follow standard safety precautions for working in hostile environments including precautions for manual handling biological hazards and personal injury The...

Page 8: ...nsure that cabling is properly connected Always switch the system on and off using the controller power button and the on off switch on the Power Supply Unit PSU The PSU is integrated within the Power...

Page 9: ...nvironment If using a generator follow the manufacturer s instructions on load connection and sequencing In the absence of these instructions the following guidelines should be used When starting the...

Page 10: ...r appropriate personal protective equipment PPE when handling the P550c Always use heavy duty industrial gloves when withdrawing a rod from a sewer Battery precautions The controller contains a Li Ion...

Page 11: ...i Ion batteries must be disposed of properly use an approved recycling facility for electronic waste Camera precautions Warning The camera will get hot with use This is normal To avoid risk of burns d...

Page 12: ...ts are heavy If available use the wheels to assist transport Observe heavy lifting safety practices when lifting any component of this system For the system weight and dimensions see the specification...

Page 13: ...0c features 20 1 2 Definitions 21 1 3 Safety notices 21 1 4 Training 22 1 5 Updates and latest information 22 1 6 Pearpoint technical support 22 2 Quick Start 23 3 System overview 25 3 1 Controller 25...

Page 14: ...4 3 Command module 69 4 4 Controller 72 4 5 Pushrod reels 76 4 6 Cameras and accessories 78 4 7 Battery 87 5 System setup 93 5 1 Insert the fuse 93 5 2 Power on the controller 94 5 3 Setup wizard Set...

Page 15: ...28 5 8 Set up a video title page 129 6 Operating the system 135 6 1 Before you begin 135 6 2 Confirming the system equipment 136 6 3 Emergency stop 137 6 4 Crawler Deployment 137 6 5 System stop 149 6...

Page 16: ...Zero the camera distance 169 6 11 Streaming images to a nearby device 171 6 12 Record a video 174 6 13 Video tools 181 6 14 Replay a video 188 6 15 Take a photo directly 190 6 16 Turn off the camera...

Page 17: ...isting surveys 199 7 4 Export a survey 204 7 5 Observations 221 7 6 Reports 230 7 7 Video streaming 233 7 8 Menu shortcuts 235 7 9 Supported survey standards 236 8 WinCan PC connections 239 8 1 Ethern...

Page 18: ...er specifications 262 12 2 Drums and PSU 264 12 3 Crawlers 265 12 4 Elevators 266 12 5 Lighthead 267 12 6 Crawler cameras 267 12 7 Crawler wheels and spacers 268 12 8 Controller to drum PSU link cable...

Page 19: ...t is easy to transport and deploy enabling quick and successful inspections The P550c controller can drive any combination of compatible pushrod reels and cameras Its 12 1 307mm screen displays the ca...

Page 20: ...eporting Survey reports videos and observation photos can be exported to USB memory sticks sent as email attachments or uploaded to DropBox MSCC3 through MSCC5 survey standards are supported Surveys c...

Page 21: ...position before you start the survey See page 169 where this is described for pushrod systems and the same principle applies for crawler systems Setting a zero distance is also known as zeroing the c...

Page 22: ...place accidents how to diagnose and repair simple issues as well as facilitating longer product lifetimes For more information go to www pearpoint com or contact your local Pearpoint representative 1...

Page 23: ...oth powered off Note This Quick Start section assumes that the controller battery is charged For details about charging the battery see page 87 2 Set up the controller a Optional Mount the controller...

Page 24: ...ed to the controller then press Select Otherwise change the equipment as necessary highlight Continue then press Select For full details about these steps see page 136 4 Deploy the crawler and camera...

Page 25: ...n Video pictures and inspection reports are stored on a high speed high capacity 128GB internal solid state storage The P550c controller is compatible with the full range of P550c P350 drums crawlers...

Page 26: ...ystem overview www pearpoint com 26 Controller front view Fig 3 1 Controller front view 1 On Off button Switches power ON or OFF When the system is powered on the on power indicator on the handle ligh...

Page 27: ...4 Handle mounted status indicators On the back and front of the handle LEDs indicate the controller s WiFi Power and Battery Charge status see page 29 5 Panel buttons Allow you to record and play sur...

Page 28: ...e back and front of the handle LEDs indicate the controller s WiFi Power and Battery Charge status See page 29 2 Main connection panel Includes a socket for the link cable to the pushrod reel an exter...

Page 29: ...troller can detect available WiFi networks It does not indicate that the controller is connected to the internet 2 Power Lights up when the controller is powered on green 3 Battery charge Lights up wh...

Page 30: ...DC power input from mains supply or vehicle supply Warning Use only the supplied battery chargers mains or optional vehicle 2 Video input An RCA video jack provides an input from external video equip...

Page 31: ...utput Allows you to display live video on an external monitor Video replay on an external monitor is not currently supported 2 For manufacturer use only 3 USB sockets Allows you to connect a USB memor...

Page 32: ...Zero the camera distance See page 147 for details 3 Sonde LED Green when active 4 Mute microphone LED is red when microphone or headset is muted 5 Recording LED Red when video recording in progress 6...

Page 33: ...system settings and rotate the video feed It also shows real time system information crawler distance since being zeroed see page 169 and the Mimic see page XX for information provided by this graphi...

Page 34: ...Survey title 6 Menu button Shows or hides button labels 7 Settings button Opens the system menus 8 Set distance button Press to zero the camera distance for a new survey 9 Joint scan button Press for...

Page 35: ...arge above 90 This will dramatically increase the number of charge and discharge cycles that the battery can achieve Only charge your battery at temperatures of 10 40 C 50 104 F See below for more det...

Page 36: ...powered or manual drum that can accommodate cable lengths of 100m 330 150m 495 200m 660 250m 820 and 305m 1000 The powered drum contains an integral power supply whilst the manual drum requires an ex...

Page 37: ...t com 37 Powered drum Fig 3 8 Powered drum including integrated PSU showing how the command module is mounted 1 Command module support stand 2 System on off switch Note the P550c controller has a sepa...

Page 38: ...nstantly shuts off system power When initiated the system must be reset 7 Pushrod connector Connect and power compatible P340 pushrod systems to your P550c controller 8 Pendant Controller connector fo...

Page 39: ...P550c Operation Manual 3 System overview www pearpoint com 39 Manual drum and PSU 13 Cable drum Houses up to 305m 1000 of cable 14 Cable brake...

Page 40: ...view www pearpoint com 40 15 Crank handle socket 16 Command module support clamp 17 PSU link cable socket 18 Manual layering handle To assist with laying cable evenly on the drum 19 Cable rollers 20 L...

Page 41: ...6 diameter Fig 3 9 P354 crawler with Forward View camera installed and P356 crawler with pan tilt and zoom camera large elevator and lighthead installed Both crawlers are compatible with a choice of t...

Page 42: ...offer automatic TILT protection By default this will halt the crawler in hazardous tilting situations when its roll first exceeds 35 The user will be shown a tilt hazard warning and can restart the cr...

Page 43: ...iler holds the pushrod and camera on a revolving drum The P550c system supports the reels below See page 155 for reel specifications Fig 3 11 P550c pushrod reels 1 P543c P343 reel 2 P542c P342 reels a...

Page 44: ...reel type 2 Stowage hooks Use for storing the link cable on the pushrod reel 3 Link cable socket Connects the link cable to the reel 4 Brake Not shown Located on reverse side of reel Adjustable to co...

Page 45: ...color camera options are available Fig 3 13 P540c pushrod cameras 1 1 25mm diameter camera for up to 4 100mm diameter pipes 2 1 32mm diameter self leveling camera for up to 6 150mm diameter pipes 3 2...

Page 46: ...the end of the pushrod helping the camera to negotiate small radius bends 2 Sonde Optional purchase Attaches to the end of the pushrod and transmits a signal allowing the sonde s position to be pinpoi...

Page 47: ...al skids Protect the camera during use and center the camera in the pipe For instructions on how to prepare the skids and cameras for use see page 83 2 Plumbers skidball For 1 25mm cameras this skidba...

Page 48: ...the preface of this document for further information Caution Before attempting to assemble the system ensure that the power is switched off Caution Check that all the link cables are connected as per...

Page 49: ...l 4 System assembly www pearpoint com 49 menu incorrect wheel settings will cause motor strain incorrect behaviors and early life failure on the crawlers Fig 4 1 P356 crawler assembly showing some of...

Page 50: ...eels are 62mm 2 5 diameter and the medium wheels are 110mm 4 3 diameter The P356 uses small medium and large wheels which can also be doubled up to improve traction This allows its use for centralized...

Page 51: ...top and the abrasive wheels below Note Item 6 V seals prevent debris ingress into the crawler seals on the medium and large wheel sets It is beneficial to check and replace these at regular intervals...

Page 52: ...pes The small abrasive rasp wheels should use the 62mm wheel size setting while the large abrasive rasp wheels should use the 110mm wheel size setting 84mm Slim Profile Wheels 84mm wheels improve perf...

Page 53: ...failure Double large wheel adaptors configuration Comprised of 2 full sets of P356 Large wheels 8x and 4x adaptors allowing the large wheels to be mounted in a tandem configuration Designed to increa...

Page 54: ...P550c Operation Manual 4 System assembly www pearpoint com 54 Fig 4 6 Pipe clearance diagrams part 1...

Page 55: ...P550c Operation Manual 4 System assembly www pearpoint com 55 Fig 4 7 Pipe clearance diagrams part 2...

Page 56: ...P550c Operation Manual 4 System assembly www pearpoint com 56 Fig 4 8 Pipe clearance diagrams part 3...

Page 57: ...bright LEDs for optimum lighting Cameras can be fitted direct to the crawler s body or to an elevator or lighthead The cameras can only be fitted in one alignment A single 3mm Allen key screw is used...

Page 58: ...Pan and Tilt camera P350 CAM PT The Pan and Tilt camera allows clear vision of pipes With focal range from 10mm to infinity featuring a 210 lm light source Pan Tilt and Zoom camera P350 CAM PTZ camera...

Page 59: ...the P354 in pipes up to 300mm 12 and the P356 in pipes up to 380mm 15 Adjustable elevator The adjustable elevator will deploy the P354 in pipes up to 350mm 15 and the P356 in pipes up to 458mm 18 Larg...

Page 60: ...to right Fixed elevator Large Adjustable elevator and Powered elevator Large adjustable elevator To fit the large adjustable elevator to the P356 crawler follow these steps 1 Align the four mounting...

Page 61: ...n Manual 4 System assembly www pearpoint com 61 Fig 4 12 Installing the large adjustable elevator 2 To adjust the height of the elevator use the supplied chuck key to twist the square recessed socket...

Page 62: ...bly www pearpoint com 62 Fig 4 13 Adjusting the large adjustable elevator Powered elevator Install the powered elevator using the following steps 1 Fit the baseplate to the top of the P356 crawler usi...

Page 63: ...oosen off the thumbscrew at the rear of the elevator so that there is plenty of play in the mechanism 3 Line the elevator up with the P356 crawler and slide the shoe projecting from the bottom of the...

Page 64: ...eed to remove the baseplate even when inspecting smaller pipes Setting the powered elevator height Warning Never place hands clothes or foreign objects into the mechanism of the powered elevator Cauti...

Page 65: ...teering sensitivity may be affected at high camera elevations Auxiliary Lighthead This can be used to provide the camera with more light With more light you can deploy the crawler in larger pipes or i...

Page 66: ...d Crawler connection Once you have fitted the crawler with the cameras wheels and other accessories you can connect it to the cable drum Connect the crawler cable termination to the terminal on the ba...

Page 67: ...4 16 Cable termination Caution Older products may feature a strain relief assembly and a stainless steel spring guard at the cable end as shown below Contact Pearpoint for assembly details Fig 4 17 O...

Page 68: ...er access points The deployment tools can deploy and remove the crawler in conduits up to 16 5 5m deep Using all 3 of the supplied poles Refer to page 167 for a guide to crawler deployment 4 2 Drums E...

Page 69: ...be left un blanked Note The Powered drum is capable of winding in deployed cable When retrieving the cable the drum will rewind slightly faster than the crawler is reversing in order to keep tension...

Page 70: ...peration Manual 4 System assembly www pearpoint com 70 Fig 4 19 P550c rear connections Connect the other end of the link cable to the controller terminal on the powered drum or external PSU Link cable...

Page 71: ...ctor on manual PSU The connector on the Powered Drum is also marked Controller External monitor An external monitor can be connected to the P550c controller using a high quality HDMI cable Plug the ca...

Page 72: ...ual drum with the supplied clamp or onto the optional vehicle wall mounting kit the height can be adjusted on the powered drum support column Tighten the wingnut at the rear of the P550 hand tight to...

Page 73: ...chnical staff can do this USB memory stick You must use a USB memory stick not supplied to install software upgrades You can optionally use a USB memory stick to import your company logo onto the cont...

Page 74: ...external keyboard to a USB port on the auxiliary connection panel see page 31 Note The controller does not support a mouse Headset Optional You can use a headset with a microphone to record and hear...

Page 75: ...System assembly www pearpoint com 75 Fig 4 21 P550c on off button and front connections showing headset socket and installed USB memory stick Headset socket Front USB socket with memory stick inserted...

Page 76: ...r pushrod directly to the labeled connector on the Powered Drum or manual Drum PSU Note Whenever you connect new equipment to the P550c controller enter the information into the Equipment menu within...

Page 77: ...y www pearpoint com 77 Fig 4 23 Link cable 1 connects to the pushrod reel 2 Tighten the connectors finger tight but do not use a wrench spanner or pliers Note You must select the reel type when you po...

Page 78: ...lements Always attach the cameras and accessories in a dry clean environment Camera Attach the camera to the pushrod Then focus the camera to match the pipe diameter 1 Check the camera lens Make sure...

Page 79: ...a s view is displayed on the controller screen b Position the camera at the required distance from a suitable target object see Table 4 1 on page 80 c Use the camera s focus tool supplied with the sys...

Page 80: ...ance from camera Inches mm Inches mm 1 25mm Camera 1 25 32 3 0 76 1 5 38 3 6 92 2 51 4 8 122 3 76 7 2 183 4 102 9 6 244 2 50mm Camera 2 51 5 6 142 3 76 8 4 213 4 102 11 2 284 6 152 16 8 427 8 203 22 4...

Page 81: ...D7100DL you can locate and track the camera as it navigates a pipe Flexisonde This sonde built in on P541c P341 Plumbers reels fits between the pushrod and the camera allowing the system to better neg...

Page 82: ...lexi to the camera This is a flexible spring attachment that allows the camera and pushrod to negotiate sharp bends in the pipe The universal flexi fits on the pushrod between the rod termination sock...

Page 83: ...rors when estimating water levels and the location of pipe deformations Each pushrod system comes with a universal skid set that allows you to adapt your camera and pushrod for deployment in pipes fro...

Page 84: ...P550c Operation Manual 4 System assembly www pearpoint com 84 Fig 4 28 Different diameter configurations that can be achieved using the universal skid set...

Page 85: ...P550c Operation Manual 4 System assembly www pearpoint com 85 Fig 4 29 Universal skid set for 1 25mm camera and flexisonde...

Page 86: ...P550c Operation Manual 4 System assembly www pearpoint com 86 Fig 4 30 Universal skid set for 2 50mm camera and 1 4 36mm flexisonde...

Page 87: ...lar 3 Make sure the camera is touching the screw end of the collar Then tighten the two M6 x 20mm screws evenly and firmly to re tighten the collar 4 7 Battery The P550c controller has an internal lit...

Page 88: ...P550c Operation Manual 4 System assembly www pearpoint com 88 For advice on prolonging the battery life see page 35...

Page 89: ...o charge the battery 1 Use the supplied mains adapter power brick to connect the controller to the mains power supply The controller s power socket is on the main connection panel on the rear of the c...

Page 90: ...n on page 33 You also can check the battery level at any time by pressing the Battery check button page 29 If the battery charge is low you can Adjust the Power Management settings For example you can...

Page 91: ...roller to your vehicle s DC power connector typically the cigarette lighter or cigarette charging point The controller s power socket is on the main connection panel on the rear of the controller see...

Page 92: ...eplace the battery yourself With typical constant usage the controller battery will last around two years If the battery reaches the end of its useful life and you can no longer recharge it the batter...

Page 93: ...veys 5 1 Insert the fuse A 5A 32V MINI blade fuse is supplied separately with the controller You must insert the fuse before powering on the controller for the first time Open the cover of the auxilia...

Page 94: ...potentially lethal electric shock To power on the controller 1 Open the two covers 2 Press the power button to switch on the controller page 26 The power LED on the handle is green when the controlle...

Page 95: ...unches automatically The wizard comprises several menus where you can set preferences and company details Follow these steps 1 Power on the controller for the first time The setup wizard launches auto...

Page 96: ...elect the Continue menu item The date and time are shown on the controller screen and optionally overlaid on video recordings see page 106 Note You will need to manually adjust the controller s time t...

Page 97: ...0m or 0 0ft Then select the Continue menu item The camera distance is shown on the controller screen and optionally overlaid on video recordings see page 106 Your chosen distance units are also used w...

Page 98: ...ntroller will use these details to personalize the title page of your survey reports You can also import an image of your company logo though you may prefer to do this later see page 128 Fig 5 5 Basic...

Page 99: ...Then select the Continue menu item You will then continue to the controller home screen If you have a pushrod connected you will be advised to rewind the pushrod fully onto the reel coiler Make sure t...

Page 100: ...s in the top left hand corner referring to the drum and either the crawler or pushrod that is connected The different icons displayed and what they represent are P550 drum Crawler Pushrod In normal op...

Page 101: ...e and camera distance are shown on the screen You can also add your company details these details are included in your survey reports From the main Settings menu you can access Controller settings see...

Page 102: ...nu Go to the home screen and press the Settings button page 33 If necessary press the Back button to go back to the home screen Navigate the menus Do the following To browse items in a menu use the Up...

Page 103: ...P550c Operation Manual 5 System setup www pearpoint com 103 Fig 5 6 Settings menu...

Page 104: ...ng the Down button will loop the cursor back to the top of the menu Language distance units keyboard layout You can set up the controller for your locale For example you can set the language for menus...

Page 105: ...rom the pushrod camera But if required you can connect an external camera to the controller and display video Camera This option displays video input from the pushrod camera Auxiliary This option disp...

Page 106: ...your survey videos and photos If this setting is disabled this information is hidden Date time hide show This setting displays or hides the date time Distance hide show This setting displays or hides...

Page 107: ...hoice Choose where on the screen to display the date time and crawler distance attitude You can display this information at the top bottom or center of the screen or on the left or right All hidden To...

Page 108: ...e overlaid text Video title page You can add a title page to the start of your survey videos Title page duration Specify how long in seconds the title page is displayed when a video starts This settin...

Page 109: ...ou enable it To set up a title page see page 129 Observation text overlay You can choose for observations to be overlaid as text on the recorded video Show observation text on video Specify whether to...

Page 110: ...automatically display whether you have a steerable or non steerable tractor connected Tractor wheel size Enter the wheel size correctly to ensure that distances are measured correctly Caution Setting...

Page 111: ...measurements will be inaccurate and your survey may be unusable Reel power off on Use this setting to turn the reel camera off or on Note If the battery level is low on your controller turn off the c...

Page 112: ...reports strictly complying with a given standard Turn off one or both options when you would like the increased flexibility for entering freeform text Enter Return key moves to next line Enabling thi...

Page 113: ...P550c Operation Manual 5 System setup www pearpoint com 113 Network settings Use this screen to set how the controller connects via WiFi and Ethernet...

Page 114: ...r a WiFi network You will need an internet connection to send survey reports by email or upload them to Dropbox Fig 5 8 Network settings 1 WiFi status 2 Network list 3 Auto Connect button 4 Scan butto...

Page 115: ...network Connected to a WiFi network but no internet connection Connected to a WiFi network with an internet connection Enable WiFi Disable WiFi When you enable WiFi the controller automatically scans...

Page 116: ...Down buttons or the arrow keys to select the network you want Then press the Connect button Wait while the controller connects to the selected network While the controller is connected to a network th...

Page 117: ...first time 1 Show Password button Auto connect Use the arrow keys to select a network Then press the Auto connect button to select the network s check box In future sessions the controller will autom...

Page 118: ...vailable networks each time you enable WiFi But you can press the Scan button to manually refresh the network list Ethernet settings Use this screen to set whether the controller s IP assignment is au...

Page 119: ...used to control the inspection equipment Enable remote control When you enable remote control the controller allows a PC connected to it by Ethernet to take control of the crawler camera and other ins...

Page 120: ...nter the SMTP Username for the account you want to use when sending emails from the controller Note Some email services including Gmail will use the SMTP Username attribute as the sender s address ins...

Page 121: ...ore you use this feature you must have a Dropbox account and the controller must be connected to the internet To set up a Dropbox connection 1 Select Connect to Dropbox from the Dropbox settings menu...

Page 122: ...one box to the next Note We recommend that you do not use your personal Dropbox account Instead use a company account or a custom account specifically for storing survey reports Fig 5 10 Dropbox logi...

Page 123: ...n prompted allow Pearpoint to create a subfolder inside your Dropbox folder tree see page 220 for details about the target subfolder Fig 5 11 Pearpoint access request 1 Cancel and Allow buttons To sig...

Page 124: ...dimming the screen If the controller keyboard or buttons are not used before the timeout expires screen brightness is reduced to its lowest level Shutdown after idle minutes This setting automatically...

Page 125: ...m components This data can be used by Pearpoint support staff to diagnose controller issues Format USB disk Use this setting to reformat your USB memory stick to FAT32 The controller does not support...

Page 126: ...igate to Continue and press Select You will be shown a pop up containing information specific to your controller Fig 5 12 Feature disabled pop up containing the information required to enable your con...

Page 127: ...and press Select This will result in a message saying that the feature has been installed successfully and the cert asc file should now be listed in Enabled features If this is not the case please co...

Page 128: ...use any of the controller s USB ports Note The image file must be smaller than 2MB 2 In the Home screen press the Settings button item 6 on page 33 3 Choose Settings Company Details 4 Scroll to the bo...

Page 129: ...only 1 Your company logo 2 Your company name address and phone number 5 8 Set up a video title page This task is optional You can set up a title page for all your survey videos If the video title pag...

Page 130: ...e video will not gain a title page if you subsequently set up a title page Instructions for designing a title page are on page 131 Can I set a custom title page Yes If you design the title page to inc...

Page 131: ...mple the company name or phone number You cannot change the company name phone number etc from this menu only decide whether or not they are displayed To make changes select Settings then Company deta...

Page 132: ...repeatedly until the item you want is highlighted in red b Use the arrow keys on the keyboard to position the item on the screen c Graphics only Press the Enlarge or Shrink buttons to resize the item...

Page 133: ...have designed the title page see page 131 2 In the Home screen press the Settings button item 6 on page 33 3 Choose Settings Screen Overlay Video title page 4 Set the Title page duration in seconds Th...

Page 134: ...are unaffected In particular if an existing video does not have a title page it will not gain a title page if you subsequently enable the video title page 6 The change is saved automatically Press Esc...

Page 135: ...re you begin Assess your deployment and safety requirements before you begin Different environments may pose risks and challenges that you may be unaccustomed to Check that no hazardous gases or vapor...

Page 136: ...time the controller and tractor system are switched on you are prompted to select and confirm the equipment attached using the Equipment settings menu Whenever you change any part of your system go t...

Page 137: ...otate the Emergency Stop button clockwise and then switch the power back on Switch the power off before disconnecting any system components or if the system is not yet connected 6 4 Crawler Deployment...

Page 138: ...may be unaccustomed to Check that no hazardous gases are present The P550c flexitrax is not suitable for use in potentially explosive environments We recommend the use of downhole and manhole rollers...

Page 139: ...ol may have any of the following components 1 3 poles 6ft 1 8m length 2 Crawler hook 3 P356 Large Elevator grab system 4 P356 crawler strap 5 P354 crawler strap Fig 6 3 Crawler deployment tool compone...

Page 140: ...ler without the Large Manual Elevator you must fit the relevant crawler strap Using two P354 M4 x 6 SKT CAP SS or four P356 M6 x 8 SKT CAP SS screws supplied secure the strap to the crawler body as sh...

Page 141: ...awler hook to the bottom pole using the screw 3 8 16 UNC 2 HEX HD SS and nut 3 8 x16U NC NYLOC SS provided Fig 6 5 Strap hook assembly Large Elevator Assembly When using a large elevator you must use...

Page 142: ...ttach the bracket to the large elevator assembly following these steps 1 Remove the 4 M6x16 screws using a 4mm Allen key 2 Remove the 4 bushes and friction o rings from the linkage arms 3 Fit the new...

Page 143: ...ure the bracket to the elevator assembly using the new 4 off M6x12 screws supplied with the lifting tool and tighten firmly recommended torque 8Nm or 70 In Lbs Fig 6 7 Elevator bracket assembly O ring...

Page 144: ...y poles as required ensuring that the push button is fully engaged Fig 6 8 Poles assembly Using the deployment tool Once ready you can use the deployment tool you can hook the strap or engage the crad...

Page 145: ...he cradle is properly engaged to the strap or elevator bracket before trying to lift the crawler We recommend the use of a suitable rope to stabilize and aid the deployment retrieval operation Use the...

Page 146: ...egular intervals to help prevent the risk of biological contaminations from foul water sources Use appropriate gloves when cleaning the system Cable deployment rollers The optional cable deployment ro...

Page 147: ...ed the crawler in the manhole using manhole rollers to protect the cable and ensuring that the cable protection spring has cleared the drum rollers you should zero the distance counter The zero 0 0 po...

Page 148: ...an integrated multi frequency sonde The Sonde allows you to locate the crawler s position using a Radiodetection cable and pipe locator such as an RD5100S or RD7100DL You can choose the transmitting f...

Page 149: ...joystick down will also stop the system See page 156 for details on using the joysticks When using the Pendant for safety this is controlled via the Pendant or the emergency stop button on the drum Pr...

Page 150: ...eel size before you attempt to drive the crawler Note You must be at the home screen to drive the crawler or powered drum If you open a menu at any time while the drum or crawler are moving they will...

Page 151: ...actor or the powered drum whichever you have selected This means that in manual tractor mode the tractor drives unassisted and the drum does not recall the cable Pearpoint recommends using AUTO mode a...

Page 152: ...l tractor and drum buttons In manual mode the LED corresponding to the chosen mode will light the manual tractor indicator LED is green and the manual drum indicator LED is yellow In AUTO mode both LE...

Page 153: ...the cable counter reaches 0 0 Reversing Caution When reversing or retrieving the crawler ensure that the cable is retrieved at the same or higher speed than the crawler Failure to do so may cause the...

Page 154: ...l automatically stop when the cable counter reaches 0 0 However the crawler s momentum may cause it to roll a short distance beyond the 0 0 position Please allow for this when you deploy the camera an...

Page 155: ...l 6 Operating the system www pearpoint com 155 the side panel closest to the controller socket The panel is secured with socket head screws Remove this panel using a metric Allen key Fig 6 13 Crank ha...

Page 156: ...ler will steer left and right allowing you to navigate pipes with ease The crawler steers by changing the speed on the left or right motors You can steer the crawler when it is moving or when it is st...

Page 157: ...ront back joystick axis controls the acceleration of the crawler The left right axis controls the steering of the P356 crawler Pressing down on the joystick will bring the crawler to a stop The right...

Page 158: ...Topple warning shows at the bottom of the screen Note that the MIMIC also shows a high tilt angle Powered elevator control The associated buttons control the elevator position when the powered elevato...

Page 159: ...tion Manual 6 Operating the system www pearpoint com 159 Fig 6 15 Powered elevator control buttons Pressing both buttons at the same time resets the powered elevator moving it to its lowest position R...

Page 160: ...ange of features to help you locate faults in more demanding conditions These are controlled by the right hand joystick and buttons Fig 6 16 Right hand joystick and camera lighting control buttons Cam...

Page 161: ...sitioning mode you have chosen You can choose between Direct and Go To See page 163 for details Camera focus control The and o control the camera s focus for far away objects and o for close objects P...

Page 162: ...ght entering the camera giving a darker picture The and control the camera s iris Pressing and holding either button continues the iris operation in that direction Pressing both buttons together reset...

Page 163: ...target in the MIMIC see page 164 Remembering that the MIMIC provides a 2D image of the 3D camera position place the target where you want the camera to point and press the joystick button down the cam...

Page 164: ...P550c Operation Manual 6 Operating the system www pearpoint com 164 Fig 6 17 MIMIC with Camera Go To target and Joint Scan icon Go To target in the MIMIC Joint Scan icon...

Page 165: ...rod completely Make sure the pushrod is layered evenly and correctly onto the reel and the end of the rod is level with the rod guide 2 Power on the controller 3 In the Equipment settings menu select...

Page 166: ...coiled on the reel rewind the rod completely Then press Calibrate Fig 6 18 Calibration reminder 1 Advisory to rewind the rod 2 Calibrate button If you connect a pushrod directly to the P550 controller...

Page 167: ...P550c Operation Manual 6 Operating the system www pearpoint com 167 Fig 6 19 Equipment settings menu for 1 Reel type 2 Reel power off on shown in the On position 2 1...

Page 168: ...pushrod Caution Pushrods can self propel and cause injury to the operator We recommend that you adjust the brake slowly to prevent the reel unwinding too quickly You can adjust the brake lever positi...

Page 169: ...oy the camera down into a manhole before starting the survey To ensure accurate camera distances are recorded in your survey videos and observations you need to zero the camera distance when the camer...

Page 170: ...oint com 170 Follow these steps 1 Get the camera in the survey start position see page 168 2 Press the Set distance button or panel button and reset the distance to 0 00 3 Make sure the on screen dist...

Page 171: ...ser Pearpoint recommends Chrome 71 to 74 Safari 12 or later or Microsoft Edge contact Pearpoint for version information and WiFi hotspot capability Connecting to a nearby connected device Firstly enab...

Page 172: ...arpoint com 172 Fig 6 21 Network settings menu The WiFi IP address to be copied to your device s browser is highlighted and enter it into the address bar of your device s browser and press Go 3 The st...

Page 173: ...isplay image streaming to a nearby device s display here an Android phone s Chrome 72 browser If you encounter difficulties check that your browser is compatible with this feature see above You can al...

Page 174: ...ideo format and size The P550c system saves survey videos as MP4 files encoded in H 264 for video and MP3 for audio The controller limits individual MP4 files to 4GB corresponding to a survey video of...

Page 175: ...About the panel buttons Use the panel buttons to record play pause and stop a video You can also capture still images ie observation photos The panel buttons are located below the controller screen s...

Page 176: ...re shown in the lower right screen A red dot on the screen indicates that recording has started Also the red Recording LED will light See page 32 The mic symbol indicates whether audio recording is on...

Page 177: ...rd a new video 1 Optional Connect a headset to record an audio commentary 2 Press the panel button twice to automatically set up a basic survey and start recording 3 Now carry out the video inspection...

Page 178: ...see page 202 Format Choose one of the following Basic survey You do not need to specify any details at this point If required you later edit the survey head to specify the operator the person carryin...

Page 179: ...203 Press the arrow keys to move through all the header fields Fields with buttons have a drop down menu For drop down menu shortcuts see page 233 Press Save to save the form 6 Applies to Structured a...

Page 180: ...ing to the survey standard chosen a pop up menu Multiple video recordings may be displayed Press Yes if you want to add a VVR condition code to the observations otherwise press Esc or the Back button...

Page 181: ...ght a pipe defect with an on screen arrow or circle On screen indicators A red dot and video counter are shown on the screen when the controller is recording a video Pause a video While a video is rec...

Page 182: ...when a survey is open For example you can take photos while recording or playing a video You can also take photos directly Any photos taken while a survey is open are listed in the survey report when...

Page 183: ...video you can add text and shapes to highlight pipe defects These overlays are displayed over the video footage Fig 6 24 Adding overlay items to a video recording 1 Overlay text and shapes Buttons 2...

Page 184: ...mp4 video and overlay graphics and captions using third party video editing software Follow these steps 1 Start recording a survey video see page 171 2 Press the panel button to pause the recording wh...

Page 185: ...le the overlay Press the Enable overlay button Do not omit this step You must enable overlays to make them visible in your video recording They will stay visible until you disable overlays in step 8 7...

Page 186: ...is enabled by default so you can immediately start speaking into the microphone 3 Optional To mute the microphone press panel button To unmute and resume audio recording press the button again To list...

Page 187: ...Attach a headset or speakers to the covered audio socket on the front of the controller item 3 on page 26 You must use speakers with a 3 5mm audio jack you cannot connect USB or Bluetooth speakers to...

Page 188: ...video is attached to While the video is playing you can stop pause forward and rewind and add new observations Fig 6 25 Video playback screen 1 Next observation button 2 New observation button 3a 3b...

Page 189: ...tons are available The playback buttons allow you to stop and pause the video view and add observations and fast forward or rewind the video 6 To stop playing the video press the panel button or Stop...

Page 190: ...efect Follow these steps 1 Open an existing survey page 200 Or create a new one page 195 Photos are saved as observations and each observation must be associated with a survey 2 Deploy the camera into...

Page 191: ...s the panel button page 32 or the New observation button to take the photo The photo shows exactly what is on the screen at the time including any overlay text or shapes camera rotation date time and...

Page 192: ...t com 192 5 The New Observation screen displays showing the new photo 6 Fill in the fields required by the survey standard see page 223 Then press the Save button to save the observation details and p...

Page 193: ...ery level is low on your controller you can turn off the camera to save battery power 1 In the Home screen press the Settings button item 6 on page 33 2 Choose Settings Equipment 3 Set the Reel power...

Page 194: ...en handling the equipment After you complete the survey wind the reel to retrieve the camera from the pipe 1 Release the brake 2 Carefully layer the pushrod onto the reel by a combination of rotating...

Page 195: ...e home screen page 33 press the Create survey button 2 In the Create survey dialog set the survey details Name The survey name defaults to the current date and time but you can set a custom name Forma...

Page 196: ...l Press the Edit survey name button and enter a descriptive name b Fill in the fields required by the survey standard The current field is highlighted in gray Mandatory fields are highlighted in yello...

Page 197: ...P550c Operation Manual 7 Surveys www pearpoint com 197 The Edit Survey screen displays page 198 You can now set up a video title page page 129 or start a recording a video page 171...

Page 198: ...video title page edit the survey header details and add or manage survey observations Fig 7 2 Edit survey screen 1 New observation button 2 List observations button 3 Title page button 4 Edit survey...

Page 199: ...3 Manage existing surveys Use the Existing Surveys screen to manage your existing surveys Fig 7 3 Existing surveys screen 1 Select Multiple button 2 Delete Selected button 3 Export Selected button 4 S...

Page 200: ...en displays see page 198 Search for a survey You can quickly search for surveys by ID title or survey type Follow these steps 1 In the home screen press the Existing surveys button 2 In the Existing S...

Page 201: ...in reverse order To restore surveys sorted by ID simply close and reopen the Existing Surveys screen Delete surveys You can delete old surveys to free up disk space on the controller s internal stora...

Page 202: ...ar again Or simply press the Unselect or Unselect all buttons e Press the Delete selected button to delete the selected surveys Rename a survey By default the survey title is set to the current date a...

Page 203: ...ey header button 4 When the Survey Header screen opens tab to the field you want and enter the new details The current field is highlighted in gray Mandatory fields are highlighted in yellow Press the...

Page 204: ...y report XML You can optionally export survey reports in XML For example you may want to import your P550c surveys into a third party system The exported file is export xml Survey videos Survey videos...

Page 205: ...u cannot export them as email attachments Export options If exporting a survey to USB or Dropbox you can choose any combination of export options If exporting a survey to email you can only export the...

Page 206: ...en the network list appears use the arrow keys to select the WiFi network you want Then press the Connect button Wait while the controller connects to the selected network If the WiFi network has inte...

Page 207: ...teps 1 In the Network Settings screen use the arrow keys to select the WiFi network you are currently connected to Then press the Disconnect button The connection icon reverts to not connected 2 Use t...

Page 208: ...multiple surveys Follow these steps a Press the Select multiple button b Use the arrow keys to highlight a survey Then press Enter or the space bar to select the survey s check box c Repeat step b for...

Page 209: ...er s USB ports 2 In the Select USB disk screen select your USB memory stick 3 Optional Specify the survey options see page 205 That is choose which items to export a Press the Export options button b...

Page 210: ...to change the email sender and server details 3 In the Send Email screen page 211 you must specify the email recipient s You can also write a brief message Recipients To quickly choose a previous reci...

Page 211: ...urveys www pearpoint com 211 Fig 7 5 Send email screen 1 Recipient 2 Subject Can be edited 3 Optional Message 4 Attachment filename Can be edited Email send failure If your email failed to send possib...

Page 212: ...be adjusted which may require you to login to your e mail account from a PC or mobile device An example of the Gmail security settings is shown below current as of writing this manual For other e mail...

Page 213: ...P550c Operation Manual 7 Surveys www pearpoint com 213 Fig 7 6 Gmail account home...

Page 214: ...eys www pearpoint com 214 Fig 7 7 Gmail Security Scroll down to Less secure app access and click on Turn on access not recommended Fig 7 8 Gmail Less secure app access Finally click on the slider to t...

Page 215: ...P550c Operation Manual 7 Surveys www pearpoint com 215 Fig 7 9 Gmail Less secure app access...

Page 216: ...mail the recipients are saved automatically to an address book You can quickly add these recipients again when sending new surveys Fig 7 10 Managing email recipients 1 Address book 2 Recipient check b...

Page 217: ...row keys to highlight a recipient 2 Press Enter to select or clear the recipient s check box Or press the Select unselect button 3 Do one of the following Press the Add recipients to email button to a...

Page 218: ...ton to connect to a different WiFi network 2 Optional If required press the Dropbox settings button to change or update the authentication details for a valid Dropbox account See page 121 3 Optional S...

Page 219: ...ways uploaded to a subfolder below the Pearpoint Cloud folder By default this subfolder is based on the controller ID and survey ID but you can specify a custom subfolder See page 220 for a full descr...

Page 220: ...oud Controller ID Survey ID Where Controller ID is the serial number that uniquely identifies the controller unit used for the survey and survey ID is the sequential ID number assigned to your survey...

Page 221: ...rt Observations are used to give a detailed yet concise description of your findings For example you can record pipe defects connections and debris Fig 7 13 Example observation with 1 photo Video reco...

Page 222: ...For French and Spanish structured surveys the controller supports the relevant EN13508 standards These condition codes describe the physical condition of the pipe or manhole inspection chamber and th...

Page 223: ...ses automatically and the controller saves a photo The photo shows exactly what is on the screen at the time including any camera rotation date time and camera distance These on screen details are con...

Page 224: ...ypes for example broken pipe cracks and defective connections require a clock reference see page 229 Fig 7 14 Field with example drop down menu 1 Drop down menu indicator 5 Press the Save button to sa...

Page 225: ...ents that correspond to observations when you play back a video Follow these steps 1 Play the video see page 188 2 Press the Next observation button to jump to each observation in turn Note You can al...

Page 226: ...n the survey that you want to manage In the Edit Survey screen now displays see page 198 3 In the Edit Survey screen press the List observations button 4 In the Observation List screen use the arrow k...

Page 227: ...e Use the arrow keys to select a survey c In the Edit Survey screen press the List observations button d In the Observation List screen use the arrow keys to select an observation e Press the Delete o...

Page 228: ...ist screen use the arrow keys to highlight an observation Then press Enter or the space bar to select its check box f Repeat the previous step each observation you want to delete Or press the Select a...

Page 229: ...nding from 2 o clock to 5 o clock To help you record these defects accurately when you type 1 to 12 in a Clock field a pop up observation photo is shown with a superimposed clock face that highlights...

Page 230: ...DOCX reports a title page shows your company details and if specified your company logo The report also includes observation photos and a drain sewer diagram or manhole inspection chamber diagram show...

Page 231: ...ee page 233 for the full survey list 1 Start node reference 2 Direction Shows whether the camera was pointing downstream with the flow or upstream against the flow 3 Finish node reference 4 Observatio...

Page 232: ...s These diagrams are included in MSCC Manhole Inspection Chamber survey reports see page 233 for the full survey list Fig 7 19 Example manhole inspection chamber diagram for survey report Observations...

Page 233: ...the display of the flexiprobe P550c to a nearby connected device such as a cell phone or tablet by following these steps 1 Connect your device as a hotspot to the flexiprobe P550c 2 Open the Settings...

Page 234: ...r address bar and press Go 6 The streamed video will show in the browser as shown above If you encounter difficulties check that your browser is compatible with this feature see step 5 above Also move...

Page 235: ...ters Example In a Weather field type r to automatically select R Rain Example In a Code field type fw to filter the menu to only show flow codes such as FW C Clear flow and FW T Turbid flow You can al...

Page 236: ...vant to each standard MSCC3 MSCC4 Domestic Drain Sewer MSCC4 Sewerage Drain Sewer MSCC4 Sewerage Manhole Inspection Chamber MSCC4 Highways Drain Sewer MSCC5 Domestic Drain Sewer MSCC5 Sewerage Drain S...

Page 237: ...rs who wish to generate reports compliant with WinCan reporting PC software In the Create survey menu select WinCan survey from the Format drop down menu Fig 7 21 Create survey menu showing WinCan sur...

Page 238: ...as other surveys WinCan survey reports Users can export to USB or using a WiFi hotspot via email or to DropBox Exports to DropBox and via email contain an xml format file that can be imported into a W...

Page 239: ...bled PC their flexitrax P550c controller to control their P550c system Firstly connect the HDMI output of the P550c to the video input of the PC using a relevant adapter if necessary Then follow the s...

Page 240: ...n adapter such as a USB to Ethernet converter Note For most set ups any good quality Ethernet cable is suitable but using a crossover Ethernet cable can help solve some connection issues particularly...

Page 241: ...Ethernet IP matches your selected IP address 10 Confirm that the P550c controller s Ethernet icon in the top right hand corner of the display shows that the connection is enabled as shown in Figure 8...

Page 242: ...P550c Operation Manual 8 WinCan PC connections www pearpoint com 242 Fig 8 1 Network settings screen showing Remote control enabled 1 the Ethernet icon signifying a good connection 1...

Page 243: ...Fig 8 2 Ethernet settings screen with values that allow control of the P550c system by a WinCan VX enabled PC 12 Press Back or Esc to return to the Start up screen 13 On the PC enter the Network and S...

Page 244: ...ss 18 Enter the IP address 169 148 1 121 19 Set the Subnet mask to 255 255 255 0 20 Click on OK to leave Internet Protocol Version 4 21 Select OK again to leave Ethernet DVC2 Properties 22 Open WinCan...

Page 245: ...P550c Operation Manual 8 WinCan PC connections www pearpoint com 245 Fig 8 3 WinCan VX screen showing the IP address box 27 Select OK to return to the Select Devices page...

Page 246: ...Select OK to return to the main WinCan VX page 30 Select Projects and open a new or an existing project 31 Select Set distance and enter a new distance and select OK 32 Confirm the new distance is di...

Page 247: ...with Ethernet cables Power up the router Note For most set ups any good quality Ethernet cables are suitable but using a crossover Ethernet cable between the P550c controller and the router can help...

Page 248: ...display shows that the connection is enabled as shown in Figure 8 1 A line through the icon means that you do not have a connection Please repeat the steps above to ensure all values have been entere...

Page 249: ...Fig 8 5 Ethernet settings screen with values that allow control of the P550c system by a WinCan VX enabled PC 8 Press Back or Esc to return to the Start up screen 9 On the PC enter the Network and Sh...

Page 250: ...nection page 16 Right click the DVC2 Ethernet connection and select Properties 17 Double click Internet Protocol Version 4 18 Select Use the following IP address 19 Enter the noted IP address and Subn...

Page 251: ...point com 251 25 From the WinCan screen go to Home Settings OSD Select device 26 Select Pearpoint P350 from the first device drop down menu 27 Select Configure the device 28 Enter the controller IP ad...

Page 252: ...P550c Operation Manual 8 WinCan PC connections www pearpoint com 252 Fig 8 6 WinCan VX screen showing the IP address box 29 Select OK to return to Select Devices page...

Page 253: ...elect OK to return to the main WinCan VX page 32 Select Projects and open a new or an existing project 33 Select Set distance and enter a new distance and select OK 34 Confirm the new distance is disp...

Page 254: ...ation the drum and crawler icons are green and the pushrod is white The different icons displayed and what they represent are Drum icons Crawler icons Pushrod icons Normal operation Normal operation N...

Page 255: ...ot permit user servicing of our systems We recommend that you only assemble or disassemble system components for example attaching the camera to the rod in a dry and clean environment We recommend tha...

Page 256: ...nk cable connections between the controller and drum and the connections between cable and crawler between crawler and lighthead if used and between lighthead and camera Check that any O rings are cle...

Page 257: ...competent mechanical technicians using a screwdriver Spare rods and various components are available to purchase as repair kits Caution If the rod wears through the rod guide it will start to wear thr...

Page 258: ...nation clean and sanitize the P550c with a suitable disinfectant at regular intervals and after conducting an inspection When cleaning the system consider your working environment Camera Clean water a...

Page 259: ...Home screen press the Settings button item 6 on page 33 2 Choose Settings Maintenance Factory Reset 3 When the controller restarts a setup wizard launches automatically The wizard comprises several me...

Page 260: ...the latest version available on the Pearpoint web site If a newer version is available it displays a Software Update advisory Go to step 2 Alternatively you can manually check whether a software updat...

Page 261: ...his ensures a reliable power source 5 On your controller select Settings Maintenance Software Update and follow the on screen instructions 6 Wait while the controller updates the software This process...

Page 262: ...nnectivity and 802 11 b g n WiFi Construction High impact ABS and powder coated zinc plated mild steel Controllers flexitrax P550c command module with integrated controls for the crawler camera lights...

Page 263: ...6V 3 75A 60W Recording formats Video H 264 Audio MP3 File format MP4 Report File Formats Basic reports MSCC3 4 docx MSCC5 docx or Xml WinCan Xml Video MP4 Image JPEG Storage Integral 128Gb and support...

Page 264: ...Hz 1 2kVA Inverter or generator to have sine wave output P350 Power supply 110 240V 50 60Hz 1 2kVA Inverter or generator to have sine wave output Construction Powder coated steel chassis frame with st...

Page 265: ...on Brass and Stainless Steel Ingress protection IP68 Ingress sealing Rated to a depth of 100m 330 of water Sonde frequency Selectable 512Hz 640Hz 8kHz 33kHz Sonde detection depth Up to 3m 10 Inclinome...

Page 266: ...305 900mm 12 36 775 1360mm 30 54 900 1500mm 36 60 Construction Stainless steel Anodized Aluminum Stainless steel Anodized Aluminum Stainless steel Anodized Aluminum Stainless steel Anodized Aluminum...

Page 267: ...2 5 12 6 Crawler cameras Cameras Forward view Pan Tilt Pan Tilt Zoom Functions Forward view only Pan 270 Rotate 360 Pan 270 Rotate 360 Zoom 3x digital 3x digital 10x optical Resolution 540TVL 540TVL 5...

Page 268: ...eaded tires for use in larger pipes P356 for pipes larger than 375mm 15 Dual pneumatic wheels Stack pneumatic tires 2 wide for additional grip or to raise camera position Rasp wheels Abrasive style wh...

Page 269: ...269 12 8 Controller to drum PSU link cables Link cables To connect P550c system modules together lengths available Controller to PSU Powered drum 1m 3 5m 16 PSU to manual drum 1m 3 3m 10 10m 32 25m 82...

Page 270: ...n a 152mm 6 Medium standard None Small standard None 203mm 8 Double stacked medium standard None Medium standard None 254mm 10 Medium standard Fixed Double stacked medium standard None Medium standard...

Page 271: ...Large adjustable 533mm 21 n a n a Large standard Large adjustable Double stacked large standard Large adjustable 610mm 24 n a n a Large standard Large adjustable Double stacked large standard Large ad...

Page 272: ...P550c Operation Manual 12 Specifications www pearpoint com 272 12 10 Crawler configuration examples See page 53 for examples of how to configure your crawlers for different pipe diameters...

Page 273: ...x 10 6 570 x 430 x 269 mm 22 4 x 16 9 x 10 6 570 x 430 x 269 mm 33 5 x 29 5 x 16 5 850 x 750 x 420 mm 32 0 x 46 0 x 18 7 813 x 1168 x 475 mm Weight 21 lbs 9 kg 27 lbs 12 kg 24 lbs 11 kg 40 lbs 18 kg 5...

Page 274: ...te Stainless steel sapphire glass polycarbonate Power 1 8W 1 3W 3 8W Environmental IP68 to 330 100m 11bar IP68 to 230 70m 7bar IP68 to 330 100m 11bar Focus Adjustable Fixed Adjustable Focal Range 10mm...

Page 275: ...the product on screen menu under Maintenance Open source software You may obtain the complete Corresponding Source code from us for a period of three years after our last shipment of this product by s...

Page 276: ...P550c Operation Manual 13 Open Source Software www pearpoint com 276...

Page 277: ...ow to prolong 35 lifespan typical 36 safety precautions 10 temperature effect on charging 35 before you begin 2 biological precautions 10 brightness 104 brushes 47 attaching 83 calibration 165 reminde...

Page 278: ...troller settings 104 date and time setting 96 daylight saving time 96 debug log 125 delete a survey 201 diagnostics 125 diagrams drain and sewer 231 manhole and inspection chamber 232 disposal of the...

Page 279: ...onnection 206 keyboard 73 language choosing 95 layout choice for screen overlays 107 lithium ion battery See battery log files 125 main connection panel 30 maintenance 255 Maintenance settings 124 man...

Page 280: ...20 power management 124 power on the controller 94 quick start 23 rechargeable battery See battery recipients managing 216 recording a video storage capacity of controller 73 recording a video 177 rec...

Page 281: ...up wizard 95 shipping the system 258 shortcuts for drop down menus 235 skids 47 attaching 83 w skids 87 SMTP username 120 software updates 260 software versions 125 sondes 46 81 sort the survey list 2...

Page 282: ...83 updates 260 USB exporting to 209 front controller port 27 rear controller ports 31 USB memory sticks 73 FAT32 reformatting to 125 vehicle recharging the battery 91 video coding formats 204 video t...

Page 283: ...rpoint com 283 enabling 115 network list 114 status indicators 115 switch to different network 207 wizard See setup wizard wraps around menu scrolling 104 WRc MSSC standards 236 w skids 87 zero distan...

Page 284: ...dgeley Boulevard Unit 34 Concord Ontario L4K 4B7 Canada Tel 1 905 660 9995 Toll Free 1 800 665 7953 rd sales ca spx com www radiodetection com Radiodetection Ltd UK Western Drive Bristol BS14 0AF UK T...

Page 285: ...60 rd sales asiapacific spx com www radiodetection com Radiodetection Australia Unit H1 101 Rookwood Road Yagoona NSW 2199 Australia Tel 61 0 2 9707 3222 rd sales au spx com www radiodetection com Rad...

Reviews: