background image

 

 

 

 

 

CONTENTS 

 
 

 

Product Features and Specifications ........................................................1 

 

Installation Requirement .......................................................................3 

 

Steps of Installation .............................................................................4 

 

Exploded View ....................................................................................19 

 

Test Run ............................................................................................25 

 

Operation Instruction ..........................................................................26 

 

Maintenance ......................................................................................26 

 

Trouble Shooting ................................................................................28 

 

Parts List ..........................................................................................29 

 
 
 
 
 
 

 
 

 

 
 

 

 

Summary of Contents for PX09

Page 1: ...PX09 PX09A X400 X400A...

Page 2: ...CONTENTS Product Features and Specifications 1 Installation Requirement 3 Steps of Installation 4 Exploded View 19 Test Run 25 Operation Instruction 26 Maintenance 26 Trouble Shooting 28 Parts List 29...

Page 3: ...n fit for a wide range of vehicle car to van and light truck Optional Jack with hand pump air operated hydraulic pump Optional Turnplate Model PX09A X440A SPECIFICATIONS Model Lifting Capacity Lifting...

Page 4: ...r a wide range of vehicle car to van and truck Optional Jack with hand pump air operated hydraulic pump MODEL PX09 SPECIFICATIONS Model Lifting Capacity Lifting Height Min Height Lifting Time Overall...

Page 5: ...MENT A TOOLS REQUIRED Rotary Hammer Drill 19 10 4 Hammer Level Bar English Spanner 12 Ratchet Spanner With Socket 28 Wrench Set 8 14 15 17 19 Carpenter s Chalk Screw Sets Tape Measure 7 5m Pliers Lock...

Page 6: ...ion and must be of test strength 3 000psi 210kg cm minimum 3 Floors must be level and no cracks C POWER SUPPLY The electrical source must be 2 2Kw minimum The source cable size must be 2 5mm and in go...

Page 7: ...5 1 2 Illustration of scissors lift PX09 X400 on surface installation See Fig 5 1 3 Illustration of scissors lift PX09A X400A on surface installation See Fig 6 Fig 5 Fig 6...

Page 8: ...stallation Flush mount installation 2 1 Flush Mount Installation Foundation Fig 7 2 2 Illustration of scissors lift PX09 X400 flush mount installation Fig 8 Fig 7 Fig 8 Power input 4 2 52mm Air source...

Page 9: ...7 2 3 Illustration of scissors lift PX09A X400A flush mount installation Fig 9 B Check the parts before assembly 1 Packaged lift and control cabinet See Fig 10 Fig 10 Fig 9...

Page 10: ...de the lift with fork lift or hoist and open the outer packing carefully 2 1 Parts for lift of on surface installation See Fig 11 Fig 12 For Model PX09A X400A For Model PX09 X400 Fig 11 PI PII 78 PI P...

Page 11: ...ts for lift of flush mount installation See Fig 13 Fig 14 Note Need guide ramps for flush mount installation For PX09A X400A Fig 13 80 81 Guide ramp 510018 PI PII PI PII Guide ramp 510019 Fig 14 For P...

Page 12: ...See Fig 15 Fig 16 4 Check the parts of the parts bag according to the parts bag list 4 1 Pasts bag for lift of on surface installation See Fig 17 Fig 18 For Model PX09A X400A For Model PX09 X400 Fig...

Page 13: ...Model PX09 X400 C Layout the model and install oil system and air line system 1 Select a location and layout the model according to steps A See Fig 21 22 The control cabinet can be installed on the l...

Page 14: ...12 2 Connecting the oil hose and air line See Fig 23 Fig 22 PII PI Fig 23 For Model PX09 X400 Connect to the A of Air solenoid valve PI PII 1Hose 1 4 2240 2Hose 1 4 4860 3Hose 1 4 4860...

Page 15: ...he air pressure to 0 4 0 6MPa See Fig 25 Fig 24 Connect the air source by the oil water separator 64 12 11 12 8 66 62 65 63 Clockwise to increase the air pressure Counter clockwise to reduce the air p...

Page 16: ...mal relay in case of different hydraulic power unit 2 Wire connection of hydraulic power unit 380V 2 1 Connect the power wire and limit switch wire according to the wiring diagram See Fig 27 Hydraulic...

Page 17: ...plex 2 Fuse FU1 25A 11 Push button LOCK Duplex 3 Fuse FU2 3A 12 Push button Down1 Triple 4 AC contactor KM 24V AC 13 Push button Down2 Duplex 5 Thermal relay FR 12A 18A 14 Motor M 3 Phase 6 Time relay...

Page 18: ...QS 380V AC 10 Push button UP Duplex 2 Fuse FU1 25A 11 Push button LOCK Duplex 3 Fuse FU2 3A 12 Push button Down1 Triple 4 AC contactor KM 24V AC 13 Push button Down2 Duplex 5 Thermal relay FR 12A 18A...

Page 19: ...hen fasten it with ratchet spanner See Fig 33 Note The tightening torque for the anchor bolt is 117N m Tap anchor bolts into the anchor hole at least 90mm deep Using the anchor bolt to fix the model 1...

Page 20: ...Tidy up the oil hose and air line cover the oil hose cover See Fig 35 2 Install the oil hose cover See Fig 36 34 Fig 34 Using the colloidal screw to fasten the oil hose cover 71 P1 P2 Fig 35 Fig 36 73...

Page 21: ...19 IV EXPLODED VIEW MODEL PX09A X400A Fig 37 Optional Turnplate 82...

Page 22: ...20 MODEL PX09 X400 Fig 38...

Page 23: ...21 CYLINDERS Fig 39 Add grease to lubricate regularly Add grease to lubricate regularly...

Page 24: ...22 CONTROL CABINET SPX ELECTRIC POWER UNIT 220V 50HZ 1PH Fig 40 Fig 41...

Page 25: ...3 Phase Illustration of hydraulic valve for SPX PEAK hydraulic power unit a SPX Electric power unit 220V 50HZ Single phase See Fig 43 Fig 42 Capacitor Oil return port Auxiliary hole Oil Outlet Solenoi...

Page 26: ...lectric power unit 380V 50HZ 3 phase See Fig 45 Running capacitor Start capacitor Oil return port Oil Outlet Check valve Solenoid valve Relief valve Throttle valve Fig 50 Oil return port Oil outlet Ch...

Page 27: ...e Two way valve to oil filling position See Fig 46 press the button Up and fill oil into the secondly cylinders till they are full and then hold down the button Lock for a while for bleeding air Repea...

Page 28: ...ower vehicle 1 Be sure clear of around and under the lift only leaving operator in lift area 2 Press the button Down1 until the lift low down to 600mm from ground the lift stop by the low limit switch...

Page 29: ...d take full torque If any of the bolts do not function for any reason DO NOT use the lift until the bolts have been replaced Every six months 1 Make a visual inspection of all moving parts for possibl...

Page 30: ...two power wire 2 Fill tank 3 Repair or replace 4 Repair or replace 5 Repair or Replace Lift does not stay up 1 Hydraulic solenoid valve out of operation 2 Relief valve or check valve leakage 3 Cylind...

Page 31: ...rol Cabinet 1 1 13 520016A Secondly Safety Lock Tube 1 1 14 520017B Secondly Cylinder 1 1 15 510017 Cylinder Limit Tube 2 2 16 520020 Snap Ring 4 4 17 620064 Grease Fitting 24 24 18 520018A Connecting...

Page 32: ...4A Tire Stop Plate 2 0 47 620065 Shim 20 20 48 420047 Quick Fitting for Air Cylinder 2 2 49 520065 Air Line Spring 2 2 50 510015 Air Line 1 1 51 420124 T fitting 1 1 52 520069 90 Quick fitting for air...

Page 33: ...ic Cylinder 11 1 510008B Main Cylinder 1 1 11 2 520053 O Ring 1 1 11 3 520043 Head Cap 1 1 11 4 520052 Support Ring 1 1 11 5 520051 Y Ring 1 1 11 6 520050 Dust Ring 1 1 11 7 510009B Piston Rod 1 1 11...

Page 34: ...ment 1 1 12 16 620082 Terminal 1 1 12 17 420087 Fuse Base 3 3 12 18 420086 Fuse FU 3 3 12 19 420085 Fuse Cap 3 3 12 20 61K052 Cup head bolt 19 19 12 21 420135 Timer Relay Base 2 2 12 22 420141 Interme...

Page 35: ...mp 1 1 200 26 209107 Oil Return Pipe 1 1 200 27 209108 Filler Cap 1 1 Parts For PEAK Electric Power Unit 220V 50HZ 1 Phase See Fig 42 200A 1 209082A Motor 1 1 200A 2 209083A Motor Connecting Shaft 1 1...

Page 36: ...0B 4 209085A Relief Valve 1 1 200B 5 209113 Throttle Valve 1 1 200B 6 209086A Lock Washer 4 4 200B 7 209087A Socket Bolt 4 4 200B 8 209088A Oil Inlet Pipe 1 1 200B 9 209089A O Ring 1 1 200B 10 209090A...

Page 37: ...35 72215102 06 2013...

Reviews: