D. Install electric system
1. Adjusting the current rating of thermal relay in control box according to the different
configurations of hydraulic power unit. In general, the electric current of thermal
relay should equal or larger than that of motor. The following table shows rated
current regulation of thermal relay in case of different hydraulic power unit.
2. Wire connection of hydraulic power unit
(380V)
2.1 Connect the power wire and limit switch wire according to the wiring diagram
(See
Fig. 27).
Hydraulic power unit
3.0HP/1 phase
3.0HP/3 phase
Rated current of thermal relay
18A
12A
Fig. 26
Earth Wire
Power Wire
Hydraulic
solenoid valve
Heigh
Limit switch
Motor
Wire
Fig. 27
This point shows
the present rated
current value
Using cross screwdriver
to adjust rated current
value of thermal relay
Low Limit
switch