![Peak PX09 Installation And Service Manual Download Page 18](http://html1.mh-extra.com/html/peak/px09/px09_installation-and-service-manual_1517265018.webp)
16
3.2 Circuit Diagram
(See Fig. 30)
.
Electric Component
E. Level two platforms and install anchor bolts.
1. Check by level bar and use the shims to adjust the platforms until two platforms are
in the same level
(
See Fig.31
).
Item
Name
Code
Specification
Item
Name
Code
Specification
1
Power switch
QS
380V AC
10
Push button
UP
Duplex
2
Fuse
FU1
25A
11
Push button
LOCK
Duplex
3
Fuse
FU2
3A
12
Push button
Down1
Triple
4
AC contactor
KM
24V AC
13
Push button
Down2
Duplex
5
Thermal relay
FR
12A-18A
14
Motor
M
Single Phase
6
Time relay
KT
24V AC
15
Buzzer
H
24VAC
7
Limit Switch
SQ
(
1~2
)
10A
16
Transformer
TC
24V AC
8
Hydraulic
solenoid valve
Y1
24V AC
17
Intermediate
relay
KA
24VAC
9
Air solenoid
valve
Y2
AC 24V
Fig. 30
PII
PI
Using the Level Bar for
the measurement
Fig. 31
Single phase
Summary of Contents for PX09
Page 1: ...PX09 PX09A X400 X400A...
Page 21: ...19 IV EXPLODED VIEW MODEL PX09A X400A Fig 37 Optional Turnplate 82...
Page 22: ...20 MODEL PX09 X400 Fig 38...
Page 23: ...21 CYLINDERS Fig 39 Add grease to lubricate regularly Add grease to lubricate regularly...
Page 24: ...22 CONTROL CABINET SPX ELECTRIC POWER UNIT 220V 50HZ 1PH Fig 40 Fig 41...
Page 37: ...35 72215102 06 2013...