50
Cyclone for ARM devices User Manual
Cyclone for ARM
®
devices
6.1.2
Procedure via Buttons and LEDs
The following steps must be followed in order for the Cyclone for ARM
devices to operate properly after the Cyclone for ARM devices has been
configured:
1. Turn off the target power supply if the “POWER IN” Jack is adopted.
2. Turn off the Cyclone for ARM devices board power.
3. Set the correct Jumper settings.
4. Connect the target power supply to the “POWER IN” Jack, if applica-
ble.
5. Connect the “POWER OUT” Jack to the target board power, if appli-
cable.
6. Connect the ribbon cable to the target debug connector.
7. Turn on the Cyclone for ARM devices board power.
8. Turn on the target power supply, if applicable.
9. Press the “START” push button on the Cyclone for ARM devices.
When the “Success” LED lights up, you have successfully programmed your
target.
6.1.3
Example
When the Cyclone for ARM devices is powered up, the Idle LED is turned on.
After the user programs the contents and procedures into the Cyclone for
ARM devices on-board flash, the Cyclone for ARM devices may be used as a
Stand-Alone Programmer. Suppose the user wants to perform the following
instructions for a target device:
1) Erase Module
2) Program Module
3) Verify Module.
When the Start Button is pressed, the “Power” LED will turn on, indicating that
the Cyclone for ARM devices is powering up the target board.
Then the “Idle” LED will turn off.
Finally, if these operations have been performed successfully, the “Success”
LED and the “Idle” LED will be illuminated. One stand-alone programming
cycle will have just been completed.