If “Erase Module” is specified, the Cyclone for ARM devices will perform an
“Erase Module” on the target device after entering the Monitor Mode or BDM
mode.
Blank Check Module
If “Blank Check Module” is checked, the Cyclone for ARM devices will perform
a “Blank Check Module” on the target device.
Program Bytes
Prompts for a starting address, which must be in the module. You are then
asked to enter in hexadecimal a byte to be programmed into the current
location. Clicking the OK button will automatically advance to the next data
byte location.
Program Words
Prompts for a starting address, which must be in the module. You are then
asked to enter in hexadecimal a word to be programmed into the current
location. Clicking the OK button will automatically advance to the next data
word location.
Program Module
For this command to work, you must have previously selected an S-record
file.
Verify Module
For this command to work, you must have previously selected an S-record
file.
Verify Checksum
This command verifies the module content via a CRC calculation.
Choose Serial File
This command becomes available once a programming algorithm is selected.
It specifies the serial file that holds the serial numbers to be programmed to
the target. Please reference
CHAPTER 11 - AUTOMATIC SERIAL NUMBER
for more information about programming serial numbers.
Program Serial Number
This command becomes available once a programming algorithm is selected.
It will instruct the Cyclone for ARM devices to program the serial number to
the target once executed. As with other commands, the serial number will not
be programmed until the SAP operations are carried out. Please reference