Opera on Systems
Vitality™ Series | SL
‐
Accent™ Control
40
Adjus ng
Main
Filtra on
Filter cycles are set using a start me and a dura on. Start me is indicated by an “A” (AM) or “P” (PM) in the bo om right corner of
the display. Dura on has no “A” or “P” indica on. Each se ng can be adjusted in 15
‐
minute increments. The panel calculates the
end me and displays it automa cally.
Set
Filter
Cycle
1:
1) Repeatedly press menu key un l FLTR appears.
2) Press up arrow and BEGN will be displayed.
3) Press up arrow again and then use up or down arrow to select
fi
lter cycle start me.
4) Press menu key exit beginning me end swith to run hours.
5) Press up arrow to select run hours then press up arrow or down arrow to adjust me.
6) Press menu key to select minutes and use up arrow or down arrow to adjust me.
Filter
Cycle
2
It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall
fi
ltra on by the overlap amount. Filter Cycle 2
is OFF by default.
Set Filter Cycle 2:
1) Repeatedly press menu un l FLTR2 appears
2) Press up arrow.
3) Press up arrow again to turn on.
4) Repeat step for se ng
fi
lter 1.
Purge
Cycles
In order to maintain sanitary condi ons, the pump will purge water from plumbing by running brie
fl
y at the beginning of each
fi
lter cycle.
If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will ini ate a purge when Filter Cycle 2 is programmed to begin.
Preference
F/C
(Temp
Display)
Change the temperature between Fahrenheit and Celsius.
12/24
(Time
Display)
Change the clock between 12 hr. and 24 hr. display.
RE
‐
MIN
‐
DERS
(Reminders)
Turn the reminder messages (like “Clean Filter”) On or O
ff
.
CLN
‐
UP
(Cleanup)
Cleanup Cycle Dura on is not always enabled, so it may not appear. When it is available, set the length of me Pump 1 will run
a er each use. 0
‐
4 hours are available.
U li es
A u li es menu selec on may be accessed and is intended for quali
fi
ed service techs only.
GFCI
Test
The Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD) is an important safety device and is required equip
‐
ment on a hot tub installa on.
(The GFCI Test Feature is not available on CE rated systems.)