Menu level overview 

Type selection menu 

Store menu 

Main menu 

Next calibration curve 

Previous calibration curve 

Power off 

Show last log 
Store new log 

Power off  

Switch lower 

Switch upper 

Open this menu/enter 

Keypad symbols 

Measuring window: 

Rolling Menu 

Power ON / OFF 
Switch upper 
Switch lower 

Save  
Hold 

Autolog 

Watch saved data 

Enter suppliers  
data 

Menu: 

Enter 
Switch upper 
Switch lower 

Exit 
Enter numbers 
Enter letters 

Next or right 
Left 

Yes 

No 

Shift 
OK 

Edit Logs 

Manual Logs 

Auto Logs 

Clear Logs  

Print Logs 

Last Logs 

All Logs 

Clear Logs 

Send Logs 

Manual Logs 

Auto Logs

 

Clear Logs 

Options 

Date/Time 
Datalog Time 
Language 
Unlock 

°C/°F 
User level 
BL On Time 
Auto Off Time 
Calibrate 
Materialcalib. 
Adjust 
Password 
Reset 

Status 

Summary of Contents for RH5

Page 1: ...User Manual RH5 Humidity Measuring Device with Sword Sensor Version 1 0_en PCE Instruments 2016...

Page 2: ...orm the sensor For heavy stacks and rolls please use the optionally available sword sensor holder and the tool for removing the sword sensor holder Measurement To switch on the instrument press the ke...

Page 3: ...ative humidity the excessive moisture would condense or form fog Dew point temperature The dew point indicates the temperature that the not completely saturated air has to reach in order to be complet...

Page 4: ...page 4 Design of the device batteries slot flipside measuring value calibration curve ON OFF button temperature selection of calibration curves air humidity and temperature sensor Option interface...

Page 5: ...r ON OFF Switch upper Switch lower Save Hold Autolog Watch saved data Enter suppliers data Menu Enter Switch upper Switch lower Exit Enter numbers Enter letters Next or right Left Yes No Shift OK Edit...

Page 6: ...ase press the button Supplier s data can also be entered on the PC subsequently Switching on the display lighting Press the key briefly the display lighting switches off automatically after approx 20...

Page 7: ...until you reach the menu see image on the right Then choose Send Logs and confirm by pressing the key Now choose Manual Logs or Auto Logs and confirm with again All saved logs will be transferred to...

Page 8: ...e cable has to be plugged in at the printer Switch on the printer by pressing Now the green LED is blinking If it does not blink please change the batteries and try again Press the button at your devi...

Page 9: ...temperature of the different components is to store all components together in a room with only small temperature fluctuations minimum over night better for 24 hours Components of calibration equipme...

Page 10: ...carefully and proceed as follows Conditioning the sensor To achieve best results let the sensor adjust for two hours The temperature has to be between 20 C and 26 C If the shown measuring value diffe...

Page 11: ...factory calibration as follows Reset to factory calibration 1 Press the button two times to reach the menu point Options 2 Select the menu item Reset using the button and confirm by pressing 3 Enter...

Page 12: ...ervals for checking the instrument depend on your operational demands and the required level of accuracy In general the drift of the sensor according to the degree of use constant humidity or use with...

Page 13: ...emove the batteries For eventual resulting damages we cannot provide any warranty In case of a faulty device please contact PCE Instruments Optional accessories PC interface for printing saved data on...

Page 14: ...page 14 Notes...

Page 15: ...h German French Italian Spanish Russian 4 pcs 1 5Volt AA Alkaline batteries for approx 1800 measurements after approx 4 minutes 30 mA with display lighting 128 x 64 matrix display with LED backlightin...

Page 16: ...ing To demonstrate the importance of temperature adjustment the table below shows measuring errors due to a temperature difference of only 1 C 1 8 F between the measuring instrument and the substance...