page 8 

Print saved data 

To print your saved data, connect the device to the 
printer  using  the  printer  cable  that  was 
delivered with  your  device:  Carefully  loose

n

 the 

protection cap on the RH5. At first plug in the side 
of  the  connector  with  the  close  plastic  casing 
at the 

R

H5.  Then switch on the device.  

Not  till  then  the  other  side  of  the  cable  has  to  be 
plugged  in  at  the  printer.  Switch  on  the  printer 
by pressing 

.  Now  the  green  LED  is  blinking. 

If  it  does  not  blink,  please  change  the  batteries 
and try again. 

Press  the 

  button  at  your 

device 

until  you 

reach the menu (see image on the right). Choose 
„Print Logs“ and confirm by pressing  . 

Now  you  can  select  if  you  want  to  print  the  last 
saved  measuring  series  or  all  saved  measuring 
series (logs).  
Confirm  by  pressing 

again.  The  selected  logs 

are printed out now. 

Info: To save paper, please think of clearing the data storage regularly.

Summary of Contents for RH5

Page 1: ...User Manual RH5 Humidity Measuring Device with Sword Sensor Version 1 0_en PCE Instruments 2016...

Page 2: ...orm the sensor For heavy stacks and rolls please use the optionally available sword sensor holder and the tool for removing the sword sensor holder Measurement To switch on the instrument press the ke...

Page 3: ...ative humidity the excessive moisture would condense or form fog Dew point temperature The dew point indicates the temperature that the not completely saturated air has to reach in order to be complet...

Page 4: ...page 4 Design of the device batteries slot flipside measuring value calibration curve ON OFF button temperature selection of calibration curves air humidity and temperature sensor Option interface...

Page 5: ...r ON OFF Switch upper Switch lower Save Hold Autolog Watch saved data Enter suppliers data Menu Enter Switch upper Switch lower Exit Enter numbers Enter letters Next or right Left Yes No Shift OK Edit...

Page 6: ...ase press the button Supplier s data can also be entered on the PC subsequently Switching on the display lighting Press the key briefly the display lighting switches off automatically after approx 20...

Page 7: ...until you reach the menu see image on the right Then choose Send Logs and confirm by pressing the key Now choose Manual Logs or Auto Logs and confirm with again All saved logs will be transferred to...

Page 8: ...e cable has to be plugged in at the printer Switch on the printer by pressing Now the green LED is blinking If it does not blink please change the batteries and try again Press the button at your devi...

Page 9: ...temperature of the different components is to store all components together in a room with only small temperature fluctuations minimum over night better for 24 hours Components of calibration equipme...

Page 10: ...carefully and proceed as follows Conditioning the sensor To achieve best results let the sensor adjust for two hours The temperature has to be between 20 C and 26 C If the shown measuring value diffe...

Page 11: ...factory calibration as follows Reset to factory calibration 1 Press the button two times to reach the menu point Options 2 Select the menu item Reset using the button and confirm by pressing 3 Enter...

Page 12: ...ervals for checking the instrument depend on your operational demands and the required level of accuracy In general the drift of the sensor according to the degree of use constant humidity or use with...

Page 13: ...emove the batteries For eventual resulting damages we cannot provide any warranty In case of a faulty device please contact PCE Instruments Optional accessories PC interface for printing saved data on...

Page 14: ...page 14 Notes...

Page 15: ...h German French Italian Spanish Russian 4 pcs 1 5Volt AA Alkaline batteries for approx 1800 measurements after approx 4 minutes 30 mA with display lighting 128 x 64 matrix display with LED backlightin...

Page 16: ...ing To demonstrate the importance of temperature adjustment the table below shows measuring errors due to a temperature difference of only 1 C 1 8 F between the measuring instrument and the substance...

Reviews: