Transfer saved data to the PC 

To  send  your  saved  logs  to  the  PC,  connect 
the 

d

evice  to  your  PC  using  the  USB  cable  that 

was  delivered  with  your  device.  Carefully 
loose  the  protection  cap  on  your 

device 

and 

plug  in  the  USB  mini  B  connector.  The 
bigger connector has to conntected to a USB slot 
on your PC. 
Start  the  software  on  your  PC  and switch on your 
RH5. 
The  data  transfer  can  be  started  on 
your 

device 

or on the software: 

Starting data transfer on the 

device

Press  the 

 key  until  you  reach  the  menu  (see 

image on the right). Then choose „Send Logs“ and 
confirm  by  pressing  the 

 key.  Now  choose 

„Manual Logs“ or „Auto Logs“ and confirm with 
again.  All  saved  logs  will  be  transferred  to  your 
PC.  

Starting data transfer on the PC: 
Press  the  button  „remote  control“  in  the 
software.  A  drop-down  menu  with  several 
options opens (see image

 

below). 

For transferring the data you can select „Import 
last manual log“ (the last saved measuring series 
is transferred) or „Import all manual logs“ (all 
saved logs are

 

transferred.  

If  you  click  on  one  of  these  menu  items,  the 
transfer starts immediately. 

For  the  basic  adjustments  of  the  software  please 
look through the instructions on the 

CD.

 

Summary of Contents for RH5

Page 1: ...User Manual RH5 Humidity Measuring Device with Sword Sensor Version 1 0_en PCE Instruments 2016...

Page 2: ...orm the sensor For heavy stacks and rolls please use the optionally available sword sensor holder and the tool for removing the sword sensor holder Measurement To switch on the instrument press the ke...

Page 3: ...ative humidity the excessive moisture would condense or form fog Dew point temperature The dew point indicates the temperature that the not completely saturated air has to reach in order to be complet...

Page 4: ...page 4 Design of the device batteries slot flipside measuring value calibration curve ON OFF button temperature selection of calibration curves air humidity and temperature sensor Option interface...

Page 5: ...r ON OFF Switch upper Switch lower Save Hold Autolog Watch saved data Enter suppliers data Menu Enter Switch upper Switch lower Exit Enter numbers Enter letters Next or right Left Yes No Shift OK Edit...

Page 6: ...ase press the button Supplier s data can also be entered on the PC subsequently Switching on the display lighting Press the key briefly the display lighting switches off automatically after approx 20...

Page 7: ...until you reach the menu see image on the right Then choose Send Logs and confirm by pressing the key Now choose Manual Logs or Auto Logs and confirm with again All saved logs will be transferred to...

Page 8: ...e cable has to be plugged in at the printer Switch on the printer by pressing Now the green LED is blinking If it does not blink please change the batteries and try again Press the button at your devi...

Page 9: ...temperature of the different components is to store all components together in a room with only small temperature fluctuations minimum over night better for 24 hours Components of calibration equipme...

Page 10: ...carefully and proceed as follows Conditioning the sensor To achieve best results let the sensor adjust for two hours The temperature has to be between 20 C and 26 C If the shown measuring value diffe...

Page 11: ...factory calibration as follows Reset to factory calibration 1 Press the button two times to reach the menu point Options 2 Select the menu item Reset using the button and confirm by pressing 3 Enter...

Page 12: ...ervals for checking the instrument depend on your operational demands and the required level of accuracy In general the drift of the sensor according to the degree of use constant humidity or use with...

Page 13: ...emove the batteries For eventual resulting damages we cannot provide any warranty In case of a faulty device please contact PCE Instruments Optional accessories PC interface for printing saved data on...

Page 14: ...page 14 Notes...

Page 15: ...h German French Italian Spanish Russian 4 pcs 1 5Volt AA Alkaline batteries for approx 1800 measurements after approx 4 minutes 30 mA with display lighting 128 x 64 matrix display with LED backlightin...

Page 16: ...ing To demonstrate the importance of temperature adjustment the table below shows measuring errors due to a temperature difference of only 1 C 1 8 F between the measuring instrument and the substance...

Reviews: