Serial port configuration task list
55
IPLink 2800 Series Getting Started Guide
4 • Serial port configuration
2800(frm-rel)[0/0]#pvc 1
2800(pvc)[1]#shutdown
Check the PVC 1 status by using
show running-config
and verify that the entry shutdown occurs in the con-
figuration part responsible for this PVC.
2800(pvc)[1]#show running-config
Running configuration:
#----------------------------------------------------------------#
# #
# 2500 #
…
pvc 1
encapsulation rfc1490
bind interface wan router
shutdown
exit
…
Displaying serial port information
The following example shows the commands used to display serial port configuration settings.
HDLC Driver: 0x8496b8
=====================
Slot: 0
Number of Ports: 1
HDLC Driver: 0x8496b8
=====================
Slot: 0
Number of Ports: 1
Port: serial 0 0 0
------------------
State: OPENED
Configuration
Hardware Port: X.21
Port Type: DCE
CRC: CRC-16
Transmit Edge: Normal
Max Frame Length: 1920
Baudrate: 64000 bps
Recv Threshold: 1