Installing the VPN router
37
IPLink 2800 Series Getting Started Guide
2 • Hardware installation
Note
Pins not listed are not used.
Installing the E1 dual coaxial cables. If the PBX or switch connection provides dual coaxial cables for the E1
connection, the transmit cable from the PBX/switch connects to the RX coaxial connector. Similarly, the
receive cable from the PBX/switch connects to the TX coaxial connector.
Figure 6. Rear panel of 2803K/UI
Hazardous network voltages are present in the PRI cables. If you detach the
cable, detach the end away from the IPLink first to avoid possible electric
shock. Network hazardous voltages may be present on the device in the area
of the PRI port, regardless of power being on or off.
To prevent damage to the system, make certain you connect the
PRI cable to the PRI port only and not to any other RJ type recep-
tacle.
Hazardous network voltages are present in the PRI cables. If you detach the
cable, detach the end away from the IPLink first to avoid possible electric
shock. Network hazardous voltages may be present on the device in the area
of the PRI port, regardless of power being on or off.
To prevent damage to the system, make certain you connect the
PRI cable to the PRI port only and not to any other RJ type recep-
tacle.
WARNING
CAUTION
WARNING
CAUTION
Summary of Contents for IPLink 2821
Page 4: ...Summary Table of Contents IPLink 2800 Series Getting Started Guide 4...
Page 18: ...About this guide IPLink 2800 Series Getting Started Guide 18...
Page 114: ...114 Chapter 9 LEDs status and monitoring Chapter contents Status LEDs 121...
Page 134: ...134 Appendix E IPLink 2800 Series factory configuration Chapter contents Introduction 142...
Page 136: ...136 Appendix F Installation checklist Chapter contents Introduction 144...