Service Manual
DS 350 Modular
© PAT
Rev. - 12/18/00 // CSH.
190118_-.DOC
16
9 ANGLE
SENSORS
Measure the angle sensor supply voltage in the central unit between
terminals X1:26 (+12/24v) and X1:28 (ground).
Refer to Drawing 1.
Replace angle sensor, if damaged or adjustments
can not be made.
Check the angle sensor for damages or movement of mounting bracket.
Refer to Drawing 1 and Adjustment Procedure 3.
START
PROBLEM: Angle displayed incorrect. Crane is not in “out of load chart” condition.
Fuse blown or main board defective. Replace main board.
Refer to Drawing 2 and Replacement Procedure 4.
NEXT PAGE
Correct
mount?
Correct?
NO
NO
YES
YES
Measure the crain power supply voltage in the central unit between
terminals X1:1 (+12/24v) and X1:2 (ground).
Refer to Drawing 1.
Check wiring between crane battery and central unit.
Correct?
NO
YES