60
PA8500-VES System
System Manual | 2014
UK
CR8506-V
|
RT8506-V
TECHNICAL SPECIFICATIONS
CR8506-V
Display
3”,.backlit,.128x64.dots
Inputs
USB-ExT.
Powered USB input on the front panel - Type A socket
Emergency microphone
•.Sensitivity./.Impedance
•.Frequency.response./.S/N.ratio
Balanced.XLR-F.on.the.front.panel
Signa.level.20.mV./.10.k
W
60.÷.20.000.Hz./.72.dB
IN.1
Socket (MIC.)
•.Sensitivity./.Impedance
•.Frequency.response./.S/N.ratio
Programmable for the following modes: ON / OFF / Precedence / VOx with A.P.T.
Balanced.XLR-F.(with.possibility.of.activating.24.V.phantom.power.supply
Signal.level.Min..3.mV.-.Max.100.mV./.1,8.k
W
240.÷.20.000.Hz./.63.dB
IN.2
Socket (MIC.)
•.Sensitivity./.Impedance
•.Frequency.response./.S/N.ratio
Socket (LINE)
•.Sensitivity./.Impedance
•.Frequency.response./.S/N.ratio
Programmable for following modes: ON/ OFF / Precedence / VOx with A.P.T.
Balanced.XLR-F.(with.possibility.of.activating.24.V.phantom.power.supply)
Signal.level.Min..3.mV.-.Max.100.mV./.1,8.k
W
240.÷.20.000.Hz./.63.dB
Balanced.with.terminals(HOT-COM-GND)
Max.signal.level.1800.mV./.31.k
W
60.÷.20.000.Hz./.84.dB
AUx
•.Sensitivity./.Impedance
•.Frequency.response./.S/N.ratio
RCA stereo socket for source of sound (BGM) – Conversion to mono
Max.signal.level.1800.mV./.31.k
W
60.÷.20.000.Hz./.84.dB
Paging units
•.Sensitivity./.Impedance
•.Frequency.response./.S/N.ratio
2 RJ45 for calling (PA) units of the PMB106-G/PMB112-G or ACIO8136 ranges.
Max.signal.level.1400.mV./.85.k
W
60.÷.20.000.Hz./.83.dB
EMERGENCY UNITS
RJ45 for connection to a dedicated emergency microphone station.
Outputs
SLAVE LINK OUTPUT
•.Output.level./.Impedance
RJ45 for connection to an RT8506-V / PMD / PA8506-V unit
Max.2000.mV./.400.
W
CR8506-V LINK
•.Output.level./.Impedance
•.Sensitivity./.Input.impedance
RJ45 for connection to a CR8506-V unit
Max.2000.mV./.400.
W
2000.mV./.50.k
W
Emergency controls
•.CONTROL.INPUTS.inputs
•.CONTROL.OUTPUTS.outputs
Programmable as Normally Activated or Normally De-activated.
7.inputs.with.diagnostics.
3.relays.for.signalling.emergency.conditions.and.failures,.NO-NC-Changeover.terminals.
Precedence IN 1 - IN 2
Precedence input with terminals with 12 V
dc
.
LAN
Presa LAN Rj45 per collegamento TCP/IP a web server.
Overall
Mains.power.supply.@230V
ac
Consumption.@230V
ac
230.Vca.50/60.Hz.±10%
10.W
External.power.supply.@24V
dc
Consumption.@24V
dc
.
24.Vcc.(min.22Vcc.÷.max.28Vcc)
0,3.A
Environmental.operating.conditions
Temperature:.+5°C.to.+40°C./.Relative.humidity:.25%.to.75%.non-condensing
Mounting
Direct.to.rack.19”.(2U).
Size.of.unit.(L.x.H.x.D)
Size.of.package.(L.x.H.x.D)
482.x.88.x.220.mm
522.x.155.x.292.mm
Net.weight
Gross.weight
4,5.kg
5,5.kg
TECHNICAL SPECIFICATIONS
RT8506-V
Mains.power.supply.@230V
ac
Consumption.@230V
ac
230.Vca.50/60.Hz.±10%
12.W
External.power.supply.@24V
dc
Consumption.@24V
dc
.
24.Vcc
0,5.A
Maximum.switchable.output.power.per.single.zone
500.W
Environmental.operating.conditions
Temperature:.+5°C.to.+40°C./.Relative.humidity:.25%.to.75%.non-condensing
Mounting
Direct.to.rack.19”.(1U)
Size.of.unit.(L.x.H.x.D)
Size.of.package.(L.x.H.x.D)
482.x.44.x.220.mm
522.x.155.x.292.mm
Net.weight
Gross.weight
4.kg
5.kg