8.1 INITIALISING THE SYSTEM
The.project.of.the.audio.system.must.be.implemented.with.the.help.of.the.specific..software.(see.Section.6,.“
Configuring the system
”,.on.page.
22).
•.
Password
From.the.HOME.page,.select.the.CONFIGURATION.menu.and.press.Ok.to.confirm.your.choice..If.the.restriction.calling.for.access.with.a.
password.has.been.enabled,.the.“CONFIGURATION.ACCESS”.screen.will.appear:.enter.the.4-digit.code.of.the.password,.then.press.Ok.to.
confirm.(the.default.password.is.
3333
,.see.page.52).
•.
Resetting the BEEP
Failure.signals.may.occur.during.the.initialisation.procedure.due.to.the.differences.between.the.configuration.of.the.system.as.connected.and.the.
default.settings..To.reset.the.acoustic.signal.(beep),.access.the.“Report>.FAULT”.menu.and.press.the.RESET.key..For.details.consult.“FAULT”..
(point 8.5.3.1, page 51)
..
.
o.
Path
:.HOME./.CONFIGURATION./.
report>.FAULT.(press.RESET.key).
•.
Acquisition of impedances
From.the.MUSIC.menu,.set.all.the.outputs.with.music.“OFF”..For.details,.see.“MUSIC.menu”
(point 8.2.4, page 35).
Acquire. the. new. loading. impedances. of. the. loudspeaker. lines,. as. indicated. under. “IMP..ACqUISITION”. and. enable. the. test. by. setting. the.
measurement.tolerances.
.
o.
Path
:.HOME./.CONFIGURATION./.
set>.TOLERANCE./.SET.TOLERANCE
.
o.
Path
:.HOME./.CONFIGURATION./.
acquire>.IMPEDANCE./.IMP..ACqUISITION.(press.the.Ok.key)
•.
Diagnostics for 24 VDC power supply
If.the.auxiliary.24.VDC.power.supply.has.been.connected,.enable.the.diagnostic.test.by.setting.“24.VDC..P.S..ON”,.as.illustrated.under.“POWER.
SUPPLY”
(point 8.5.2.3, page 50).
.
o.
Path
:.HOME./.CONFIGURATION./.
set>.BACkGROUND.TEST./.4-Power.supplies
•.
Emergency messages
The.emergency.messages.are.stored.on.the.SD.card.using.the.dedicated.software.
•.
Input contacts
Use.the.dedicated.software.to.programme.the.input.contacts.in.the.appropriate.manner.on.the.basis.of.the.Emergency.and.Evacuation.Plan.
(E&EP).
.
o.
Path
:.HOME./.CONFIGURATION./.
set>.CONTROL.INPUTS
•.
Output contacts
Use.the.dedicated.software.to.programme.the.output.contacts.in.a.suitable.manner,.on.the.basis.of.system.specifications,.if.any.
.
o.
Path
:.HOME./.CONFIGURATION./.
set>.CONTROL.OUTPUT
•.
Volume control
Adjust.the.output.volume.of.the.VES.sources.suitably.so.as.to.ensure.that.the.messages.are.as.intelligible.as.possible..The.level.set.will.be.used.
for.”Voice.Alarm.Conditions”.and.will.be.the.same.for.all.the.zones..To.adjust.the.volume.of.the.Emergency.Microphone.and.of.the.ALERT.and.
EVAC.messages,.follow.the.instructions..provided.under.“ALARM.LEVEL”.
(point 8.6.4, page 55).
.
o.
Path
:.HOME./.CONFIGURATION./.
set>.ALARM.LEVEL
•.
Resetting failures
Upon.completion.of.the.system.configuration,.the.reports.concerning.failure.that.have.been.stored.and.cleared.should.be.cancelled.(RESOLVED)..
A.FAULT.RESET.should.therefore.be.carried.out.as.indicated.under.“FAULTS”
(point 8.5.3.1, page 51).
.
o.
Path
:.HOME./.CONFIGURATION./.
report>.FAULT,.access.the.subpanels.for.viewing.failures.
•.
After initialising the system
After.completing.the.system.initialisation.procedure,.LOG.OUT.in.order.to.reinstate.any.access.restrictions.associated.with.passwords.
(point
8.5.5, page 51).
.
o.
Path
:.HOME./.CONFIGURATION./.
Exit>.Logout.(press.the.Ok.key).