Instruction Manual

 is 

copyrighted with all rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, 
providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under any other 
circumstances, without the written consent of PASCO scientific, is prohibited. Rev: 12/18. 

Trademarks 

PASCO, PASCO Capstone, and 

SPARKvue are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. For more information 
visit 

www.pasco.com/legal. 

Product End of Life Disposal Instructions:

This electronic product is subject to disposal and recycling regulations that vary by country and region. It is your responsibility to recycle your 
electronic equipment per your local environmental laws and regulations to ensure that it will be recycled in a manner that protects human health 
and the environment. To find out where you can drop off your waste equipment for recycling, please contact your local waste recycle/disposal 
service, or the place where you purchased the product.

The European Union WEEE (Waste Electronic and Electrical Equipment) symbol (to the right) and on the product or its 
packaging indicates that this product 

must not

 be disposed of in a standard waste container

.

Battery Disposal Instructions:

Batteries contain chemicals that, if released, may affect the environment and human health. Batteries should be collected 
separately for recycling, and recycled at a local hazardous material disposal location adhering to your country and local 
government regulations. To find out where you can drop off your waste battery for recycling, please contact your local waste 
disposal service, or the product representative.

The Lithium Polymer (Li-Poly) rechargeable battery used in this product is marked with the International symbols to indicate the need for the 
separate collection and recycling of batteries.

Appendix A: 

Bluetooth Compatibility

Check the PASCO website at 

www.pasco.com/compatibility

.

*The PS-3500 USB Bluetooth 4.0 Adapter, when connected to a USB port, allows up to three 
Bluetooth SMART devices, such as this PASCO wireless device, to connect to Windows 
computers, Chromebooks, and older Macintosh computers. 

Note: The PS-3500 USB Bluetooth 4,0 Adapter is the only adapter we can currently recommend. 
Many other Bluetooth 4.0 adapters are available but this adapter has a specific design that 
enables in-app pairing of Bluetooth SMART sensors. 

1

To check the Mac computer’s Bluetooth compatibility, do the following:

Click the 

 (Apple) Menu.

Platform

Bluetooth SMART Compatibility

iOS

iPad 3 and later
iPhone 4S and later
iPod touch 5 and later

SPARK LX / LXi

All models

Android

Android 4.4 and later

Chromebook

Chrome OS (requires PS-3500 Adapter*)

Mac OS X

Models introduced July 2011 or later*

Windows

Windows 7 and later (requires PS-3500 Adapter*)

PS-3500 USB 
Bluetooth 4.0 

Adapter

Summary of Contents for PS-3224

Page 1: ...ommended Equipment Optical Dissolved Oxygen Metal Guard PS 3605 Required Item Part Number PASCO Data Collection Software see www pasco com Battery LED Bluetooth LED Micro USB Cable Transparent Cover E...

Page 2: ...ensor including the following Barometric pressure is recorded and stored only when the sensor is initially connected via Bluetooth or USB Initial Step Charge the Battery Connect the Cable Remove the t...

Page 3: ...In Sparkvue open the Main Menu and select Help for information about collecting displaying and analyzing data In the window that opens is the address of the web page for Help Copy and paste the addre...

Page 4: ...vue and PASCO Capstone support logging Check the PASCO Web page at www pasco com software for the latest software version Set Up the Software SPARKvue Set Up Connecting the Sensor to a Tablet or a Com...

Page 5: ...sor to a Computer with the Micro USB Cable Connect the micro end of the included Micro USB Cable into the micro USB port on the top of the sensor Connect the other end of the Micro USB Cable to a USB...

Page 6: ...issolved Oxygen Sensor Set Up the Software 6 013 16057A Select a Layout and then select a data display In the Data Display Click Select Measurement Select a measurement from the list under Sensors Sel...

Page 7: ...communicating with the computer software or tablet application try restarting the software or application If the problem remains press and hold the ON button on the sensor for 10 seconds and then rel...

Page 8: ...c pressure and salinity Temperature The rate of diffusion of oxygen through the Sensor Cap changes with temperature approximately 1 5 per degree celsius The Optical Dissolved Oxygen Probe has a built...

Page 9: ...int free cloth If necessary use a mild detergent Do not use alcohols or other organic solvents that may deteriorate the oxygen permeable diffusion layer and the sensing layer dye layer When changing t...

Page 10: ...ure of the gas in wet air or in solution is taken to be 20 9 Given this it is reasonable to use the probe in a gaseous environment to measure the oxygen present The sensor outputs a value labeled O2 G...

Page 11: ...ssolve enough sodium sulfite sodium bisulfite or potassium sulfite in 150 milliliters of distilled water such that a small amount of sodium sulfite remains undissolved in the bottom of the beaker WARN...

Page 12: ...connect pair and calibrate the other sensor s if necessary During the calibration process if you click Calibrate first point or Calibrate second point and then click Cancel the sensor will be restored...

Page 13: ...RKvue Calibration Steps Place the Wireless Optical Dissolved Oxygen Sensor into your known standard for 100 dissolved oxygen saturation 1 In SPARKvue touch or click Sensor Data in the Welcome Screen a...

Page 14: ...rdware Setup icon to open the Configure Sensors and Measurements window 5 In the Configure sensors and measurements window D02 Saturation is the default choice for calibration Touch or Click the Calib...

Page 15: ...the Calibrate Sensor Enter Values window Calibration Point 2 is the default selection with the Standard Value 100 0000 and the Sensor Value panel NOTE that the Sensor Value panel will show the number...

Page 16: ...ight arrow in the Configure sensors and measurements panel to close the panel and return to the data dis play 2 In the data display click the up arrow menu icon in the Live Data Bar to open the menu t...

Page 17: ...ing caused by exposure to light so the Sensor Cap must be replaced periodically It should also be replaced if it is cracked scratched or damaged The Sensor Cap is warranted for one year and may last m...

Page 18: ...Cap Calibration After a new Replacement Sensor Cap PS 3604 is placed on the Optical Dissolved Oxygen probe there are two parts to the Sensor Cap Calibration process First enter the Sensor Calibration...

Page 19: ...ace between each number NOTE Enter the numbers exactly as they appear on the sheet with the Calibration Code Coefficients for Cap Replacement including negative signs decimal points and other characte...

Page 20: ...n numbers from the sheet with the Calibration Code Coefficients for Cap Replacement as a list of 10 numbers separated by spaces NOTE Enter the numbers with a space between each number NOTE Enter the n...

Page 21: ...r calibration above 200 10 Resolution 0 01 mg l or 0 1 saturation Temperature C Range 0 50 Accuracy 0 1 C Resolution 0 1 C Barometric Pressure inHg Optional Units mmHg Range 375 836 mmHg Accuracy TBD...

Page 22: ...not be disposed of in a standard waste container Battery Disposal Instructions Batteries contain chemicals that if released may affect the environment and human health Batteries should be collected se...

Page 23: ...ng lower than 0x6 means an older version of Bluetooth Your device will need the PS 3500 USB Bluetooth 4 0 Adapter 1The Mac Mini and MacBook Air were updated with Bluetooth SMART support in 2011 The Ma...

Page 24: ...Wireless Optical Dissolved Oxygen Sensor Appendix A 24 013 16057A...

Reviews: