10
VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
Power Supply Connections
Power drives from a DC supply derived from an isolating transformer or a DC power supply
(See Power Supply Options later in this section).
Note: Pin 10 is at the top of the connector X1 and pin 1 at the bottom.
X1
+HV
-HV
GND
MOTOR
CONNECTIONS
PE
+24V DC
9
8
7
6
5
4
3
2
0V (GND 24v DC)
10
1
Power & motor
10-way
connector
Figure 3-1. X1 Power Connections
WARNING – Possible drive damage
If you use Parker XL Series stepper drives, do not attempt to use any power wiring
harness taken from an XL drive. Although the same mating connector is used for
both an XL and a ViX, the ViX wiring is the reverse of the XL and the wrong wiring
connection will damage the drive.
Mating connector type is: Wieland 8213B/10 F OB, Part number 25.323.4053.0 (Parker part
number 0405.811).
Supply Requirements
Power the ViX drives from DC supplies as specified below:
Volts
Drive Type
DC Supply Voltage
bHV and -HV
ViX500
48V to 80V (recommended)
ViX250
24V to 80V
Table 3-1. Drive Supply Voltages
Summary of Contents for ViX250IM
Page 3: ......
Page 52: ...44 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE...
Page 102: ...VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE 94...
Page 206: ...198 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE...
Page 218: ......