![Parker ViX250IM User Manual Download Page 141](http://html1.mh-extra.com/html/parker/vix250im/vix250im_user-manual_3955798141.webp)
6. COMMAND REFERENCE
133
1END
1MOVE1:
1USE(1)
; use the move profile 1
1G
1O(XX1)
; turn output 3 on
1T0.1
; wait for 100mS
1O(XX0)
; turn output 3 off
1END
1MOVE2:
1USE(2)
; use the move profile 2
1G
1T1
; pause for settle time
1TR(IP,=,1)
1END
Note
If you exceed the number of nesting levels the program will halt and
return a *E. R(UF) will return a ‘Program nesting overflow’ message.
If a GOTO command is used, the number of nesting levels is set to zero.