2. MECHANICAL INSTALLATION
7
Drive Mounting Options
If you require a DIN-Rail mounting ViX drive use the optional DIN-Rail clip adapter bracket
shown in Figure 2-2.
Viewed from the back
of the DIN rail
Allow 10mm
for release
57.2mm
131.2mm
16mm
Figure 2-2. DIN-Rail Adapter Bracket
Remove the panel mounting plate from the back of the drive and attach the bracket to the
back of the drive using the screws provided. The drive and bracket can now be fixed to a
DIN rail by hooking the top of the bracket over the top of the DIN rail and gently pushing the
drive forward to engage the lower section of the bracket. Remove the bracket by inserting a
flat bladed screwdriver into the release slot to pull down the bottom of the bracket, releasing
it from the DIN rail.