![Parker ViX250IM User Manual Download Page 139](http://html1.mh-extra.com/html/parker/vix250im/vix250im_user-manual_3955798139.webp)
6. COMMAND REFERENCE
131
G
Go
Syntax
Units
Range of ‘n’
Default
See also
aG
-
-
-
PS S K M
Description
Issuing a G command starts motion using the parameters specified by the V,
A or AA/AD, and D commands or via the PROFILE and USE commands.
The mode of motion must have been previously set as this determines which
parameters are used and which are ignored. For example, mode continuous
will ignore the distance parameter.
Properties
Immediate or buffered, can be used in labelled block, not saved by SV
Example
1PROFILE3(150,200,1500,25)
;define profile 3
1USE(3)
;use profile 3
1G
;perform profile 3
Note
If no motion occurs after G is issued, the cause can be determined by using
the R(UF) command. Refer to the section on system parameters for more
information.
Summary of Contents for ViX250IM
Page 3: ......
Page 52: ...44 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE...
Page 102: ...VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE 94...
Page 206: ...198 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE...
Page 218: ......