Parker LCB Series Mounting Instructions Download Page 7

Parker EME 

Introduction

 

192-510014 N06 April 2013

Hint

 

Provides important information about the product, how to handle the product or about the 
part of the manual to which particular attention must be paid. 

1.4.4. 

Working safely 

Heed the Instructions 

The information (such as instructions and notes) contained in this manual must be 
heeded for all work involved in installing, commissioning, setting up, operating, 
changing operating conditions and modes, servicing, inspecting and repairing the 
unit. 
The manual must be available close to the linear module during the performance of 
all tasks. 
It is impermissible to operate the liner module if it is not in perfectly functional 
condition. 

 

Operating personnel 

The following jobs must only be performed by appropriately trained and authorized 
personnel: 

 

Installation and set-up tasks on the linear actuator

 

Attaching safety limit switches (initiators)

 

Connecting the drive and testing the motion direction

Instructions for Special Hazards 

The linear module must be fixed or supported in accordance with the indications in 
this manual. 
The operator must ensure that operation of the linear module does not cause any 
danger. 
If the linear module moves in hazardous areas, these areas can be safeguarded 
with safety transmitter switches. 

 

1.4.5. 

Safety Instructions for the Company Using the System 

Supervisors must also become familiar with the entire chapter entitled "Safety" and 
handling required on the linear actuator. 
Supervisors must ensure that installation and operating personnel have read and 
understand the chapter entitled "Safety" and the description of how to work with the 
machine, and that they observe the instructions. 
The manual must be available close to the linear module during the performance of 
all tasks. 
It is impermissible to operate the liner module if it is not in perfectly functional 
condition. 
Depending on the application, the operating company must provide for a suitable 
separating safety fence. Access to the motion range during operation must be 
prevented. 
The user must make sure that the work area is protected by appropriate safety 
devices. 

 

1.4.6. 

Safety Instructions for Operating Personnel 

Any work step that has a negative effect on the operating safety of the linear motor 
module must be omitted. 
Operating and supervisory personnel are required to check the linear actuator or 
machine at least once per shift for externally visible damage or defects. Changes 
that have occurred (including the operating behavior) that could have a negative 
effect on the operating safety must be reported immediately. 
Components and accessories are designed especially for this product. When 
purchasing spare and wearing parts, use only original Parker parts. We note here 
explicitly that we are unable to check or release spare parts or accessories that 
were not provided by us. Installing and/or using such products may cause negative 

Summary of Contents for LCB Series

Page 1: ...11 16 16 39 192 510014 N06 April 2013 Daten entsprechen dem technischen Stand zum Zeitpunkt der Drucklegung Mounting instructions LCB Manual Installation Commissioning Maintenance and Repair LCB Compa...

Page 2: ...anical Drives Division EME Via Gounod 1 I 20092 Cinisello Balsamo MI Italy Tel 39 0 2 361081 Fax 39 0 2 36108400 E mail sales automation parker com Internet www parker com eme nonwarranty clause We ch...

Page 3: ...otes on transport 9 1 6 Warranty conditions 10 1 7 Conditions of utilization 10 2 Commissioning 11 2 1 Preparations for substructure 11 2 2 Fitting mounting 12 2 2 1 Installation of a single actuator...

Page 4: ...r actuator LCB060 1 2 Type specification plate Type specification plate example Parker Hannifin GmbH Electromechanical Automation Robert Bosch Stra e 22 D 77656 Offenburg Germany Tel 49 0 781 509 0 Id...

Page 5: ...Parker EME Introduction 192 510014 N06 April 2013 5 1 3 Mounting explanation...

Page 6: ...g as well as testing work pieces or tools Since the component can be used in a very wide range of applications the user is responsible for its use in specific applications Please make sure that the mo...

Page 7: ...s must also become familiar with the entire chapter entitled Safety and handling required on the linear actuator Supervisors must ensure that installation and operating personnel have read and underst...

Page 8: ...temperature of 0 C or below Please provide appropriate worker protection e g protective gloves Please ensure that the consignment does correspond to your order Check the product for damages Do never u...

Page 9: ...eing injured Moving parts must always be secured against slipping or moving By wrapping several turns of strong adhesive tape around the sliding carriage which if possible is in the centre of the prof...

Page 10: ...ere is a sufficient safety travel at both ends of the travel stroke Even if the limit switches were already mounted at our premises they must be adapted according to suitable values before operation S...

Page 11: ...re Each holding point must be even with a flat parallelism of 0 2 mm All holding points must be aligned with parallelism to each other of better than 0 5 mm To simplify installation and adjustment the...

Page 12: ...ng crate Place it on the leveled holding points water level leveling device Fix the module LCB mounting methods Fasten the connection parts in place Removing the protective covering adhesive tape Note...

Page 13: ...cond linear actuator if necessary Verify the horizontal alignment of the linear actuators water level leveling device and correct if needs be Fix the second actuator permanently Fasten the connection...

Page 14: ...mounted in proximity of the drive station or the deflection station Switching distance 2 4 mm if needs be an additional external buffer must be fitted Caution The software end limits are not preset F...

Page 15: ...g housing and the coupling mm 23 4 5 40 15 13 5 54 MA Tightening torque of clamping screws Nm 1 4 10 5 AL Distance between flange surface of the coupling housing and the drive station mm 8 14 Details...

Page 16: ...qualified specialists or employees of Parker Only qualified expert personnel is permitted to perform works on the linear actuator All the applicable regulations and provisions must be heeded IEC EN na...

Page 17: ...r joltily please check the following Make a visual inspection of the guiding Check for visual wear and for smoothness of the guiding surface If necessary replace profile If the force needed to move th...

Page 18: ...e plate for measurement Exchange sliding block LCB The sliding block is a wearing part You need 4 pieces per linear actuator 1 Sliding block We recommend to have at least 4 sliding blocks on stock Acc...

Page 19: ...but also the deflection station itself Remove cover in upwards direction Unscrew the two fixing screws at all four sliding blocks entirely and remove sliding blocks Mount new sliding blocks in reverse...

Page 20: ...Splits at the belt teeth Faulty belt pre tension Exchange toothed belt set pre tension Overload Exchange toothed belt set pre tension Check if the load is in the admissible range Aging of the toothed...

Page 21: ...rder to insert the new belt while removing the old one Insert ends of belt cautiously into both clamping brackets On the LCB040 first screw the clamping bracket to the sliding carriage on the side of...

Page 22: ...f the measuring procedure comes with the device 1 toothed belt tensioning screws 2 counter screws The belt is tensioned with the aid of the tensioning screws at the tensioning station loosen lock nut...

Page 23: ...tallation of a double axis actuator 13 Installation of a single actuator 12 Intended use 6 Introduction 4 M Maintenance and service 16 Maintenance schedule 17 Mounting explanation 5 O Ordering the too...

Page 24: ...Compact Linear Actuator LCB 24 192 510014 N06 April 2013...

Reviews: