Belt tension measuring device RSM
The RSM belt tension measuring device determines the tension of the belt on the
basis of preset data (specific mass of belt, freely oscillating length of belt) and the
oscillating frequency of the belt.
The belt tension measuring device can be purchased at Parker
(Part-No. 037-000202).
An operating manual with a description of the measuring procedure comes with the
device.
(1) toothed belt tensioning screws
(2) counter screws
The belt is tensioned with the aid of the tensioning screws at the tensioning
station (loosen lock nut during tensioning process and re-fasten afterwards).
After tensioning, the belt must be aligned.
An exact alignment is only possible during movement of the (sliding) carriage.
With correct adjustment, the toothed belt always oscillates from left to right (in
the driving direction).
In order to keep the pre-tension of the belt, please turn the tensioning screws only
in very small steps.
If necessary, check belt tension again after the alignment.