![Parker LCB Series Mounting Instructions Download Page 12](http://html1.mh-extra.com/html/parker/lcb-series/lcb-series_mounting-instructions_4045361012.webp)
Commissioning
Compact Linear Actuator - LCB
12
192-510014 N06 April 2013
LCB060
(1): Maximum permitted deflection
2.2
Fitting / mounting
2.2.1.
Installation of a single actuator
Note
Danger when transporting long actuators. Because the actuator bends under its own
weight, guiding accuracy may deteriorate significantly. In addition, the shape of the profile
may change and the travel behavior of the (sliding) carriage may be negatively affected.
Additional information on transport:
(see on page 8)
Note
When fitting the LCB into your system, please make sure that the deflection station and the
sliding carriage are accessible for maintenance! (Provide enough space behind the
deflection station so that the sliding blocks or the sliding carriage can be removed).
Take the linear module out of the shipping crate.
Place it on the leveled holding points (water level, leveling device).
Fix the module (LCB mounting methods)
Fasten the connection parts in place.
Removing the protective covering (adhesive tape).
Note
There are two ways to fasten the LCB in place.
Mounting with clamping profiles or
With T slot bolts/nuts that are guided into the grooves of the aluminum profile.
Mounting accessories: see in the catalog section (following the mounting
instructions).
Note
The standard installation position is horizontal with the sliding carriage up.
Optionally (after consultation with the manufacturer) a horizontal installation position with
the sliding carriage on the side or at the bottom or vertical installation are also possible.
(1)
0
500
1000
1500
2000
2500
3000
3500
4000
0,1
1,0
10000,0
10,0
100,0
1000,0
K
ra
ft
F
n / N
Stützabstand SA [mm]
0,
20 m
m
0,
30 m
m
0,
50 m
m
1,
00 m
m
2,
00 m
m
K
ra
ft
/ F
or
ce F
n /
N
Distance between mountings SA [mm]
0.1
1.0
10000.0
10.0
100.0
1000.0
0.
20 m
m
0.
30 m
m
0.
50 m
m
1.
00 m
m
2.
00 m
m